2.7. Specifications tables
2.5TL M
2.7TL M
3TL M
3.3TL M
3.68TL M
DC inputs
Recommended power range of PV array
(1)
2.8 ~ 3.3 kWp
3 ~ 3.6 kWp
3.2 ~ 4 kWp
3.8 ~ 4.3 kWp
3.9 ~ 4.8 kWp
Maximum input voltage
(2)
850 V
850 V
850 V
850 V
850 V
Voltage range MPP1
(3)
125 ~ 750 V
125 ~ 750 V
125 ~ 750 V
125 ~ 750 V
125 ~ 750 V
Voltage range MPP2
(3) (4)
90 ~ 750 V
90 ~ 750 V
90 ~ 750 V
90 ~ 750 V
90 ~ 750 V
Operating voltage range
(4)
90/125 ~ 850 V
90/125 ~ 850 V
90/125 ~ 850 V
90/125 ~ 850 V
90/125 ~ 850 V
Minimum voltage for Pnom with DC inputs
in parallel
125 V
127 V
141 V
155 V
172 V
Maximum short circuit current
(input 1 / input 2)
13 / 13 A
13 / 13 A
13 / 13 A
13 / 13 A
13 / 13 A
Maximum inverter backfeed current to the
array
0 A rms
0 A rms
0 A rms
0 A rms
0 A rms
MPPT
2
2
2
2
2
Number of strings
2
2
2
2
2
Strings per MPP
1
1
1
1
1
Maximum input current
(input 1 / input 2)
11 / 11 A
11 / 11 A
11 / 11 A
11 / 11 A
11 / 11 A
Maximum input current per string
11 A
11 A
11 A
11 A
11 A
AC output
Nominal power (up to 45 ºC)
2.5 kW
2.7 kW
3 kW
3.3 kW
3.68 kW
Maximum continuous power
2.5 kW
2.7 kW
3 kW
3.3 kW
3.68 kW
Max. temperature for nominal power
(5)
60 ºC
57 ºC
55 ºC
52 ºC
50 ºC
Maximum current
16 A
16 A
16 A
16 A
16 A
Maximum transient current
16 A
16 A
16 A
16 A
16 A
Maximum output fault current
< 18 A rms (60 ms)
Maximum output overcurrent protection
18 A rms
18 A rms
18 A rms
18 A rms
18 A rms
Rated voltage
230 V
230 V
230 V
230 V
230 V
Voltage range
122 ~ 265 V
122 ~ 265 V
122 ~ 265 V
122 ~ 265 V
122 ~ 265 V
Nominal frequency
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Cosine of Phi
1
1
1
1
1
Adjustable cosine of phi
Yes. Smax =
2.5 kVA
Yes. Smax =
2.7 kVA
Yes. Smax =
3 kVA
Yes. Smax =
3.3 kVA
Yes. Smax =
3.68 kVA
THD
< 3 %
< 3 %
< 3 %
< 3 %
< 3 %
Performance
Maximum efficiency
97.6 %
97.6 %
97.7 %
97.7 %
97.8 %
Euroefficiency
97.3 %
97.3 %
97.4 %
97.4 %
97.5 %
General data
Cooling system
Natural convection
Weight
20 Kg
20 Kg
20 Kg
20 Kg
20 Kg
Measurements (height x width x depth)
470 x 360 x 180 mm
Standby current
(6)
< 10 W
< 10 W
< 10 W
< 10 W
< 10 W
Night consumption
0 W
0 W
0 W
0 W
0 W
Operating temperature
–
25 ~ +65 ºC
–
25 ~ +65 ºC
–
25 ~ +65 ºC
–
25 ~ +65 ºC
–
25 ~ +65 ºC
Relative humidity (without condensation)
0 ~ 100 %
0 ~ 100 %
0 ~ 100 %
0 ~ 100 %
0 ~ 100 %
Maximum altitude of the installation
3000 m
3000 m
3000 m
3000 m
3000 m
Protection class
IP65
IP65
IP65
IP65
IP65
Markings
CE
EMC and safety regulations
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN
62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
Grid connection regulations
RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2,
G83/2, P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149,
ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid Code, Ecuadorian
Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements
(1)
Depending on the type of installation and the geographic location.
(2)
Never exceed this value. Consider the voltage increase of the panels ‘Voc’ at low
temperatures.
(3)
The output power will be determined by the voltage and current configuration selected at each input.
(4)
To lower it to 90 V the other
input must be at 125 V at least.
(5)
For each ºC of increase, the output power is reduced by 1.8 %.
(6)
Consumption from the PV array.
56
Unit description
Ingeteam
ABE2011IQM01_B - Installation and Operation Manual
Содержание INGECON SUN 1Play 2.5TL
Страница 3: ...iii Ingeteam ABE2011IQM01_B Deutsch DE English EN Espa ol ES Fran ais FR Italiano IT Portugu s PT...
Страница 48: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 90: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 132: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 258: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 260: ...Ingeteam Power Technology S A www ingeteam com ABE2011IQM01_B 04 2015...