Operating Instructions
Operation & Maintenance Manual
23221138 (12-07) Rev A
33
WARNING
!
Do NOT operate machine with guards removed.
CAUTION
!
Do not operate machine with safety shutdown switch bypassed.
Before Starting
•
Check battery for proper connections and condition.
•
Check engine coolant level.
WARNING
!
Do not remove pressure cap from a HOT radiator. Allow radiator to cool
down before removing pressure cap. Use extreme care when removing a
pressure cap from a liquid cooling system for the engine. The sudden
release of pressure from a heated cooling system can result in a loss of
coolant and possible severe personal injury.
•
Check the engine oil level. Maintain per marks on dipstick.
•
Check the fuel level. Add only CLEAN fuel for maximum service from the engine.
•
Check the compressor lubricating fluid level between top and midway of the sight
glass on the compressor sump sight glass.
WARNING
!
This machine produces loud noise with service valve open. Extended
exposure to loud noise can cause hearing loss. Wear hearing protection
when valve is open.
•
Close all service panels to maintain a cooling air path and to avoid recirculation of
hot air. This will maximize the life of the engine and compressor.
•
Be sure no one has any body part in the machine.
Содержание VHP40RMD
Страница 5: ...23221138 12 07 Rev A 5 Safety...
Страница 15: ...23221138 12 07 Rev A 15 Warranty...
Страница 21: ...23221138 12 07 Rev A 21 Installation...
Страница 29: ...23221138 12 07 Rev A 29 General Data...
Страница 32: ...Operation Maintenance Manual General Data 32 23221138 12 07 Rev A...
Страница 33: ...23221138 12 07 Rev A 31 Operating Instructions...
Страница 41: ...23221138 12 07 Rev A 37 Maintenance Lubrication...
Страница 50: ...Always use Ingersoll Rand Replacement parts 46 23221138 12 07 Rev A...
Страница 51: ...23221138 12 07 Rev A 47 Trouble Shooting...