58
AC-SVX002C-EN
To e
en
na
ab
blle
e security:
•
On Settings screen, click S
Se
eccu
urriitty
y button. The
Settings screen will now appear with onlyo the
Security button. It will not have a Log In/Log Out
buttons
•
Click E
En
na
ab
blle
e button, then click S
Sa
av
ve
e. The Settings
screen will now appear with Log In/Log Out button,
in addition to the Security button.
Logging Out
To log out, click L
Lo
og
g O
Ou
utt button. A confirmation screen
appears as shown below. Click Y
Ye
ess to confirm.
Figure 43.
Log out confirmation screen
InvisiSound Ultimate — Noise Reduction
Mode
When the InvisiSound
™
Ultimate option is selected
(model number digit 12=3), noise reduction mode can
be enabled to adjust fan speed and lower maximum
sound levels. Reduced acoustic noise levels can be set
for certain times, or on a schedule. The noise reduction
feature can be requested by local time of day
scheduling, external input or building automation
system.
To enable this function at the external display, access
the Settings screen on the Tracer
®
AdaptiView
™
. See
figure below.
Figure 44.
Noise reduction mode settings
•
Set the Front Panel Noise Reduction Request to ON.
•
Adjust the Noise Reduction Condenser Fan Speed
Clamp to desired value.
–
Setting for fan speed: Percentage of 920 rpm
maximum fan speed (Example: For fan speed of
700 rpm, enter a value of 76%)
–
Acceptable inputs are 60% (552 rpm) to 100%
(920 rpm) in 1% increments
Tracer TU
The AdaptiView
™
TD7 operator interface allows for
daily operational tasks and setpoint changes. However,
to adequately service chillers, Tracer
®
TU service tool
is required. (Non-Trane personnel, contact your local
Trane office for software purchase information.)
Tracer
®
TU adds a level of sophistication that improves
service technician effectiveness and minimizes chiller
downtime. This portable PC-based service-tool
software supports service and maintenance tasks, and
is required for software upgrades, configuration
changes and major service tasks.
Tracer
®
TU serves as a common interface to all Trane
®
chillers, and will customize itself based on the
properties of the chiller with which it is
communicating. Thus, the service technician learns
only one service interface.
The panel bus is easy to troubleshoot using LED sensor
verification. Only the defective device is replaced.
Tracer
®
TU can communicate with individual devices
or groups of devices.
All chiller status, machine configuration settings,
customizable limits, and up to 100 active or historic
diagnostics are displayed through the service-tool
software interface.
LEDs and their respective Tracer
®
TU indicators
visually confirm the availability of each connected
sensor, relay, and actuator.
Tracer
®
TU is designed to run on a customer’s laptop,
connected to the Tracer
®
AdaptiView
™
control panel
with a USB cable. Your laptop must meet the following
hardware and software requirements:
•
1 GB RAM (minimum)
•
1024 x 768 screen resolution
•
CD-ROM drive
•
Ethernet 10/100 LAN card
•
An available USB 2.0 port
•
Windows 7 Enterprise or Professional operating
system (32-bit or 64-bit)
N
No
otte
e:: Tracer
®
TU versions 8.6 and earlier will also
support Microsoft
®
Windows
®
XP
Professional operation system with Service
Pack 3 (SP3) .
•
Microsoft .NET Framework 4.0 or later