Refrigeration Maintenance and Service Operations
113
Figure 36: Testing for Refrigerant Leaks
8. Connect the charging hose to a source of nitrogen. Adjust the pressure regulator to 1380 kPa, 13.80
bar, 200 psig. See “Using Pressurized Nitrogen” in this manual chapter.
9. Pressurize the system with nitrogen to 1380 kPa, 13.80 bar, 200 psig.
10. Close the supply valve on the nitrogen bottle.
11. Use an electronic leak tester to inspect all joints and connections. (Use a soap solution as an
alternative test component.)
NOTE: If a system leak is indicated, loosen supply line hose fittings to release pressure. Repair leakage
condition.
12. If system repair is necessary, recheck system after repairs are completed.
Low Side Pump Down (R-134a Compressor Only)
NOTE: Do NOT pump down a scroll compressor. Reclaim the refrigerant when servicing the low side
or high side of the R-23 refrigeration system.
1. Install the gauge manifold on the compressor.
2. Set the controller setpoint temperature well below the return air temperature and operate the unit in
the Cool mode until the temperature stabilizes (at least 5 minutes).
3. Close the receiver tank outlet valve. Allow the unit to operate until it reaches -15 to -40 kPa, -0.15 to
-0.40 bar, 5 to 11 in. vacuum on the suction pressure gauge (3-5 minutes). Then shut the unit down
manually with the On/Off switch.
4. To place the unit back in service, open the receiver tank outlet valve and turn the On/Off switch ON.
CAUTION: Nitrogen (N2) is under 15,170 kPa, 151.70 bar, 2200 psig pressure in a full cylinder
at 21 C (70 F). DO NOT use oxygen, acetylene or any other type of pressurized gas in the system.
CAUTION: Never open the low side to the atmosphere while it is in a vacuum. Air and moisture
will be drawn in and contaminate the refrigerant system.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...