ColdCube Installation
17
Connecting to a 110-240 VAC Power
Source
The ColdCube has a built-in multi-voltage electrical
connection adapter with a priority circuit for connecting to a
110-240 VAC supply. The priority circuit automatically
switches to VAC operation if the ColdCube is connected to a
110-240 VAC supply, even if the 12/24 V cable is still
connected.
If both power sources are connected, AC power is selected. If
the AC power supply is disconnected or drops below 85 V AC
there will be a one minute time delay before the compressor
switches to operate on DC power. If AC power is established at
any time, there will be no delay to compressor operation.
CAUTION: Danger of electrocution! Never handle
plugs and switches with wet hands or if you are
standing on a wet surface.
Plug the AC connection cable into the
AC voltage.