background image

INTELLISYS OPTION

10

SSR UP6 15, UP6 20, UP6 25, UP6 30

27 POWER L.E.D.

This will illuminate when the 8V controller supply is available.

28 AUTOMATIC RESTART L.E.D.

This will illuminate when the machine has shutdown due to low air

demand. The compressor will restart and load automatically as soon

as the demand for air resumes.

DISPLAY MESSAGES

When the compressor is running normally, the display will indicate

the package discharge pressure and illuminate the corresponding

L.E.D. 

[1]

. An arrow will also appear in the far right of the display

indicating pressure band selection. Pressing 

display select

 

[19]

 will

change the display value and the corresponding L.E.D. will illuminate.

The controller monitors all aspects of the compressor while running and

will display warnings or in severe conditions execute an emergency

stop and display alarm conditions.

MACHINE CONTROL MODES

CAPACITY CONTROL

The compressor is designed to work with two types of capacity

control, to suit the individual plant requirements. These controls are:–

A. On line – Off line. (Fitted as standard)

B. On line – Off line, with Upper Range Modulation. (Optional extra)

Either is available by selection at the control panel.

ON LINE  – OFF LINE CONTROL

For applications that require a widely varying air demand, this

mode of control will deliver air at full capacity or zero capacity with

low receiver pressure.

This mode of operation is controlled by the pressure transducer

responding to changes in plant air pressure. This sensor energizes

the load solenoid valve which in turn operates the venting valve

(blowdown) and the closing of the atmospheric vent opening in the

air inlet valve.

The compressor then delivers full capacity air to the plant

system. If the air pressure in this system rises to the upper set point

of the pressure setting, the load solenoid valve is de–energized

allowing the inlet valve to close. At the same time, the venting valve

opens allowing the receiver pressure to drop.

The pressure setting has a range of 12 psi (0.83 bar) between

its upper and lower set points.The upper set point is set at 3 psi (0.2

bar) above the compressor rated discharge pressure.

UPPER RANGE MODULATION CONTROL

 

(Optional Extra)

For plants having a relatively high and constant air demand,

Upper Range Modulation is the recommended mode of control.

Upper range modulation retains the features of On line – Off line

control but provides the throttling of the inlet air flow as the line

pressure rises to the upper set point of the 

off–line

 pressure setting.

By bleeding off a small amount from the regulator valve, which

energises the Modulate Solenoid Valve, a reduction in the air signal

to the pneumatic cylinder on the inlet valve allows the cylinder to

‘trim’ the inlet valve position as dictated by changing line pressure.

Modulation begins when the compressor reaches about 94% of the

rated line pressure and is factory set to modulate down to

approximately 70% of rated capacity.

If the air demand decreases to a level below the 70% modulated

output, the line pressure will increase slightly to the upper limit of the

pressure setting, when the compressor then changes to the Off line

control position and operates with the receiver vented.

AUTOMATIC START/STOP

For plants that have a widely varying plant air demand, larger air

storage capacity, and/or want automatically available stand–by air

capacity, Automatic Start–Stop Control Option is available.

During periods of low demand, if the line pressure rises to the off line

air pressure set point of the lntellisys

®

, a timer is energized and begins

to time out. The automatic restart time is adjustable in a 2–60 minute

range. The timer will continue to operate as long as the plant line

pressure remains above the on line set point of the Intellisys

®

. If the

timer continues to operate for as long as its adjusted time setting, a

contact in the lntellisys opens to de–energize the compressor starter

coils. At the same time, a yellow Automatic Restart light on the

lntellisys

®

 panel is lit and the message AUTO RESTART will be

displayed to indicate the compressor has shut down automatically and

will restart automatically.

The automatic restart will take place when the line pressure drops

to the online set point of the Intellisys

®

.

To operate in the automatic start/stop mode, proceed with the

following steps:

1. Press the SET button until the message AUTO S/S OFF is

displayed.

2. Push the up or down arrows to select the auto start/stop function (on

or off). AUTO S/S OFF in the display indicates auto start/stop is

disabled (off). AUTO S/S ON in the display indicates auto start/stop is

enabled (on). Press the SET button to store function. The display will

flash to acknowledge and then display

 

AUTO S/S 10 MIN.

3. Press the up or down arrows to select the desired automatic restart

time (2–60 min. range). The default value is 10 minutes. Press SET

button to store the value.The display will flash to acknowledge. Press

the DISPLAY SELECT button or wait 30 seconds for the controller to

automatically exit the set routine.The display returns to READY TO

START.

4. Start the compressor and adjust the isolation valve to allow the unit

to slowly reach the offline pressure and unload.The compressor should

run for a minimum of 10 min. and unloaded for the pre–set time and then

shut down.

5. The compressor should restart automatically when the system air

pressure drops below the online air pressure setting.

CONTROLLER WARNING MESSAGES

In the event of a warning, the controller will display a message and

the 

alarm L.E.D.

 

[10]

 will flash. The warning message will alternate with

the normal display every 4 seconds, the compressor will continue to run

but the fault should be rectified as soon as possible. The 

arrow keys

[23]

 should be used to index the display for any additional warning

messages. A warning message may be reset by depressing 

set

 

[21]

once.

NOTE:

The warning will recur if the fault has not been rectified. The

following warning messages may be displayed:

COOLANT FILTER (OPTIONAL)

The pressure differential across the coolant filter exceeds 15 psi (1

bar)

.

AIR FILTER

The air filter is dirty or blocked and should be replaced.

SEPARATOR ELEMENT

The separator element is dirty or blocked and should be replaced.

AIREND TEMPERATURE

The airend temperature reaches 97% of the high airend

temperature set point (i.e. 223

°

F (106

°

C)).

Содержание SSR UP6 15

Страница 1: ...Dust Option Outdoor Module Option PORO Option SSR UP6 15 UP6 20 UP6 25 UP6 30 60Hz This manual contains important safety information and must be made available to personnel who operate and maintain t...

Страница 2: ......

Страница 3: ...Serial No From Serial No Not illustrated Option NR Not required AR As required SM Sitemaster Sitepack HA High ambient machine WC Watercooled machine AC Aircooled machine ERS Energy recovery system T E...

Страница 4: ...ll Rand does not accept any liability for losses caused by equipment in which non approved repair parts are installed Standard warranty conditions may be affected Ingersoll Rand reserves the right to...

Страница 5: ...Prohibition Mandatory Information Instructions Warning Use fork lift truck from this side only RESET Do not use fork lift truck from this side Emergency stop On power Off power AUTOMATIC RESTART MAINT...

Страница 6: ...6 20 UP6 25 UP6 30 Use ULTRA Plus Coolant only Failure to use the specified coolant may result in damage to the machine POWER INSPECT Every X months if sooner than required by operating hours CHANGE R...

Страница 7: ...s and vapors which can result in serious injury Never operate the compressor near flammable liquids or vapors If used to spray flammable materials keep compressor at least 20ft away from the spray are...

Страница 8: ...machine cannot be started accidentally WARNING Imposing a normal or emergency stop on the compressor will only relieve presure upstream of the minimum pressure valve on top of the separator tank If m...

Страница 9: ...ssor is left unattended Do not use extinguishers intended for Class A or Class B fires on electrical fires Use only extinguishers suitable for class BC or class ABC fires Attempt repairs only in clean...

Страница 10: ...Start 24 The compressor will start and then load automatically POWER OUT RESTART Optional If this setting is set to ON the compressor will automatically restart when power is returned to the compress...

Страница 11: ...t to display This is used to select alternative status displays after approximately5 minutes the display defaults to the package discharge pressure Depressing this button in the set point routine will...

Страница 12: ...limit of the pressure setting when the compressor then changes to the Off line control position and operates with the receiver vented AUTOMATIC START STOP For plants that have a widely varying plant a...

Страница 13: ...he emergency stop button is engaged LOW SUMP PRESSURE The sump pressure drops below 15 psi 1 bar during normal operation FIELD OPTION S Before installation and operation of this option these instructi...

Страница 14: ...INTELLISYS OPTION 12 SSR UP6 15 UP6 20 UP6 25 UP6 30 ELECTRICAL SCHEMATIC DOL WITH INTELLISYS CONTROL INTELLISYS DOL 32343956 Revision D...

Страница 15: ...out restart Optional 2ATT Temperature sensor 3APT Pressure sensor NOTES 1 Approved fused disconnect or circuit breaker per code requirementsmust be provided by customer 2 Dashed lines represent wiring...

Страница 16: ...INTELLISYS OPTION 14 SSR UP6 15 UP6 20 UP6 25 UP6 30 ELECTRICAL SCHEMATIC STAR DELTA WITH INTELLISYS CONTROL INTELLISYS STAR DELTA 32343931 Revision E...

Страница 17: ...ATT Temperature sensor 3APT Pressure sensor 1S Contactor wye star NOTES 1 Approved fused disconnect or circuit breaker per code requirementsmust be provided by customer 2 Dashed lines represent wiring...

Страница 18: ...INTELLISYS OPTION 16 SSR UP6 15 UP6 20 UP6 25 UP6 30 PIPING AND INSTRUMENTATION WITH INTELLISYS CONTROL 85584282 Revision C...

Страница 19: ...sure 12 Switch temperature 13 Filter coolant 14 Thermostat 15 Cooler 16 Relay overload Motor 17 Valve safety 18 Valve drain 19 Screen scavenge 20 Valve solenoid blowdown 21 Orifice 22 Indicator air re...

Страница 20: ...Y 1 Tank separator 2 Transducer pressure 3 Valve solenoid Line Sump 4 Connector 5 Combination block 6 Elbow 7 Tee male run 8 Reducer bushing 9 Valve solenoid Blowdown 10 Valve solenoid Load 11 Indicat...

Страница 21: ...2 2 Seal 14 22177174 1 Cabinet 15 96737564 14 Nut 16 96743182 8 Screw 17 85584340 4 Latch 18 92829308 1 Key 19 96703756 2 Nut 20 22128763 1 Controller INTELLISYS 21 22091193 2 Hinge 22 96743992 4 Scre...

Страница 22: ...et 7 32342115 1 Bus grounding 8 22132963 1 Contact auxilliary 9 39251061 1 Contactor C37 10 22074033 3 Fuse 2 0A 125 250V 11 32342099 2 Fuse 1 5A 600V 12 39479035 1 Fuse holder 13 39480504 1 Fuse hold...

Страница 23: ...ket 7 32342115 1 Bus grounding 8 22132963 1 Contact auxilliary 9 39250998 1 Contactor C43 10 22074033 3 Fuse 2 0A 125 250V 11 32342099 2 Fuse 1 5A 600V 12 39479035 1 Fuse holder 13 39480504 1 Fuse hol...

Страница 24: ...1 Bracket 7 32342115 1 Bus grounding 8 22132963 1 Contact auxilliary 9 39251020 1 Contactor C85 10 22074033 3 Fuse 2 0A 125 250V 11 32342099 2 Fuse 1 5A 600V 12 39479035 1 Fuse holder 13 39480504 1 F...

Страница 25: ...Bracket 7 32342115 1 Bus grounding 8 39251038 1 Contactor B110 9 22074033 3 Fuse 2 0A 125 250V 10 32342099 2 Fuse 1 5A 600V 11 39479035 1 Fuse holder 12 39480504 1 Fuse holder 13 39251434 3 Lug 14 32...

Страница 26: ...22132963 2 Contact auxilliary 9 39250998 1 Contactor C43 10 39251004 2 Contactor C60 11 22074033 3 Fuse 2 0A 125 250V 12 32342099 2 Fuse 1 5A 600V 13 39479035 1 Fuse holder 14 39480504 1 Fuse holder 1...

Страница 27: ...Bus grounding 8 22074413 1 Contactor C16 9 39252036 2 Contactor C23 10 22074033 3 Fuse 2 0A 125 250V 11 32342099 2 Fuse 1 5A 600V 12 39479035 1 Fuse holder 13 39480504 1 Fuse holder 14 39333257 1 Int...

Страница 28: ...15 1 Bus grounding 8 39252036 3 Contactor C23 9 22074033 3 Fuse 2 0A 125 250V 10 32342099 2 Fuse 1 5A 600V 11 39479035 1 Fuse holder 12 39480504 1 Fuse holder 13 39333257 1 Interlock 14 32342123 1 Lug...

Страница 29: ...132963 2 Contact auxilliary 9 39251061 1 Contactor C37 10 39250998 2 Contactor C43 11 22074033 3 Fuse 2 0A 125 250V 12 32342099 2 Fuse 1 5A 600V 13 39479035 1 Fuse holder 14 39480504 1 Fuse holder 15...

Страница 30: ...1 Contact auxilliary 9 39252036 1 Contactor C23 10 39251061 2 Contactor C37 11 22074033 3 Fuse 2 0A 125 250V 12 32342099 2 Fuse 1 5A 600V 13 39479035 1 Fuse holder 14 39480504 1 Fuse holder 15 393332...

Страница 31: ...Contact auxilliary 9 39252036 1 Contactor C23 10 39251061 2 Contactor C37 11 22074033 3 Fuse 2 0A 125 250V 12 32342099 2 Fuse 1 5A 600V 13 39479035 1 Fuse holder 14 39480504 1 Fuse holder 15 39333257...

Страница 32: ...cause improper operation START UP AND OPERATION Preliminary checks Before starting the compressor make sure that The power supply is correct for the dryer voltage Starting the dryer a Use the green s...

Страница 33: ...eals should the housing leak 1 Isolate the housing from the air supply 2 Fully depressurize in drain bowl as appropriate 3 Unscrew bowl and remove If pressure has not been completely released from the...

Страница 34: ...d Pipe insulation Gum synthetic Compressor Steel copper aluminium oil Condenser Steel copper aluminium Refrigerant R134a Valve Brass Electrical cable Copper PVC REFRIGERANT LEAKS IN THE REFRIGERATION...

Страница 35: ...8 48 8 F L A Current Amps 9 6 12 3 12 3 Total Installed Power kW 0 96 1 19 1 19 Electrical Protection Class Std NEMA 1 IP20 Refrigerant Type 134a Notes 1 Electrical data refers to dryer only 2 The dr...

Страница 36: ...r power inlet G Fork lift openings Fork lift hole covers must be installed after unit is in place to reduce noise and ensure proper cooling of package H Button emergency stop I Primary compressor serv...

Страница 37: ...ge F Customer power inlet G Fork lift openings H Air receiver 120 gallons I Automatic drain valve J Valve drain K Button emergency stop L Primary compressor service door M Inspection port N Dryer air...

Страница 38: ...ge F Customer power inlet G Fork lift openings H Air receiver 240 gallons I Automatic drain valve J Valve drain K Button emergency stop L Primary compressor service door M Inspection port N Dryer air...

Страница 39: ...tion 2 Valve three way bypass 3 Filter air 4 Moisture separator 5 Valve autodrain 6 Receiver air 7 Valve drain 8 Indicator dew point colour 9 Valve expansion 10 Filter refrigerant 11 Condenser 12 Evap...

Страница 40: ...g relay C1 Compressor starting capacity C2 Fan motor starting capacity UP5 18 UP5 22 UP5 18 HA UP5 18 HA Only UP6 25 UP6 30 UP6 18 HA UP6 20 HA UP6 20 HA Only QF Residual current circuit breaker by in...

Страница 41: ...Panel 3 22100648 1 Bracket 60Hz 4 22099303 1 Panel 5 95937520 1 Connector 60HZ 6 22100549 1 Tube assembly 7 22070304 1 Bracket 7A 96737564 2 Nut 7B 96705058 2 Setscrew 8 22100556 1 Bracket 9 22097968...

Страница 42: ...24 96742689 AR Screw 24A 96742689 AR Plug 25 95937652 1 Elbow 26 22070825 1 Tube assembly 27 95937520 1 Connector 28 22101083 1 Separator water 29 22098859 1 Connector 30 22070833 1 Hose assembly 31 9...

Страница 43: ...DRYER OPTION 41 SSR UP6 15 UP6 20 UP6 25 UP6 30 Fig 1 Fig 2a Fig 2b Fig 2c...

Страница 44: ...Condensing Temperature Switch 89327928 89327928 89327928 9 Main Switch with On Lamp 89236079 89236079 89236079 10 Condensate Drain Complete 89327936 89327936 89327936 11 Drain Valve for 89327936 8932...

Страница 45: ...P6 25 UP6 30 Item ccn Qty Description Item ccn Qty Description 1 36897999 1 Filter 2 35393685 1 Element air filter 3 22245534 1 Bracket 4 35295799 6 Clamp 5 89295935 2 Hose 6 96712153 2 Screw 7 221553...

Страница 46: ...OUT DOOR MODULE OPTION SSR UP6 15 UP6 20 UP6 25 UP6 30 Item ccn Qty Description Item ccn Qty Description 1 22134597 1 Cover 2 22127500 1 Louvre 3 92368687 AR Screw 4 22127328 1 Box 5 22053730 1 Louvr...

Страница 47: ...ically 10 seconds adjustable after incoming power is restored FUNCTION TEST To test the operation of the Power Outage Restart Option 1 Slowly open the main isolation valve 2 Start the compressor 3 The...

Страница 48: ...PORO OPTION ELECTRO PNEUMATIC 46 SSR UP6 15 UP6 20 UP6 25 UP6 30...

Страница 49: ...66788 8 Tie cable 3 22265946 1 Contact auxilliary 4 22396592 1 Controller LOGIC PORO 5 22140545 1 Decal PORO 6 39194097 1 Decal Power Out Restart Option 7 22388037 1 Decal Schematic 8 39331954 1 DIN r...

Страница 50: ...20 UP6 25 UP6 30 ITEM PART NUMBER QUANTITY DESCRIPTION 17 39252937 2 Block end stop 18 39309554 1 Tape adhesive 19 35246131 1 Terminal 20 39204763 1 2m 4ft Wire Blue 16 Ga 21 39129085 1 2m 4ft Wire R...

Страница 51: ...display indicates Power Outage Restart is turned on and OFF in the display indicates Power Outage Restart is turned off 5 Once the selection has been made press SET button to put the selection into I...

Страница 52: ...50 SSR UP6 15 UP6 20 UP6 25 UP6 30 Item ccn Qty Description Item ccn Qty Description 1 39194097 1 Option Module 2 35275494 1 Connector bulkhead 3 95934279 1 Nipple 4 39108949 2 Locknut 5 39146733 1 P...

Отзывы: