GENERAL INFORMATION

The compressor is an electric motor driven, contact cooled screw compressor, 

complete with all necessary components piped, wired and baseplate 

mounted. It is a totally self contained air compressor package.

The standard compressor is designed to operate in an ambient range of 2° C 

to 46° C (5° F to 115° F). The standard maximum temperature of 46° C (115° 

F) is applicable up to an elevation of 1000 m (280 ft) above sea level. Above 

this altitude, significant reductions in ambient temperature are required if a 

standard motor is to be used.

The compressor is managed by the onboard electronic controller. The 

controller and drive system operate together to vary the speed of the 

compressor to deliver compressed air at the target pressure.

For fixed speed (FS) models, the capacity is automatically controlled via 

‘ON-OFF LINE’. The compressor will operate to maintain a set discharge line 

pressure and is provided with an auto restart system for use in plants where 

air demand varies widely.

Panel instrumentation is provided to indicate the compressor operating 

conditions and general status.

The air/coolant mixture discharges from the compressor into the separation 

system. This system removes all but a few ppm of the coolant from the 

discharge air. The coolant is returned to the cooling system and the air passes 

to the aftercooler and out of the compressor through the moisture separator.

Air is pulled into the compressor by the cooling blower and through the 

coolant cooler and aftercooler.

By cooling the discharge air, much of the water vapor naturally contained in 

the air is condensed and is drained from the built-in moisture separator and 

drain.

The coolant system consists of a sump, cooler, thermostatic valve and a 

filter. When the compressor is operating, coolant is forced by air pressure 

from the separator tank to the thermostatic element. The position of the 

element (a direct result of coolant temperature) will determine whether the 

coolant circulates through the cooler, bypasses the cooler, or mixes the two 

paths together to maintain an optimum compressor discharge temperature. 

This temperature is controlled to preclude the possibility of water vapor 

condensing. By injecting coolant at a sufficiently high temperature, the 

discharge air coolant mixture temperature will be kept above the dew point.

For variable speed drive models, the system is enhanced by a control logic 

that varies the cooling blower speed dependent on the intake and discharge 

temperatures and hence controls the injection temperature even closer while 

saving blower motor energy.

The compressor is provided with a temperature sensor which will shut the 

compressor down in case of excessive temperature. This setting is typically 

109° C (228° F).

Effective coolant filtration is provided by the use of a screw on, heavy duty 

coolant filter.

NOTICE

Standard air compressors are factory filled with compressor coolant . 

It is recommended to perform a coolant analysis every 2000 hours or 

3 months to monitor condition and determine when to change the 

coolant . If an analysis is not performed, the recommended coolant 

change interval is 8000 hours or two years, whichever comes first .

For compressors supplied with optional food grade coolant, it is 

recommended to perform a coolant analysis every 500 hours or every 

month to monitor condition and determine when to change the 

coolant . If an analysis is not performed, the recommended coolant 

change intervals is 2000 hours or six months, when utilizing the food 

grade filter supplied with the compressor . For compressors running 

food grade coolant without the food grade filter, the change interval 

should be 1000 hours or three months, whichever comes first .

NOTICE

Fixed speed compressors should not be connected to variable speed 

drives . Please contact your local Ingersoll Rand representative before 

inverter duty conversion .

CAUTION

For fixed speed models, the compressor may not reach its normal 

operating temperature during periods of low demand . Sustained 

operation at low demand can result in the buildup of condensate in 

the coolant . If this situation occurs, the lubricating characteristics 

of the coolant can be impaired, which may lead to damage of the 

compressor .

The compressor should be allowed ample loading time .

Integrated Dryer Operation

In the default mode, the dryer is non-cycling. The stop button must be 

pressed to shut off the dryer.

In the energy efficient mode, the dryer may run up to 6 minutes before 

it shuts off automatically during the Start/Stop mode of the compressor 

package. Note the dryer could be off for an extended period if the 

compressor needs to come back on right away.

NOTICE

If ISO Class 4 dew point standards are critical to your application, 

run the compressor in unload mode (fixed speed) or idle mode 

(variable speed) for one minute at startup to allow the dryer to reach 

the required dew point before the compressor begins providing 

compressed air .

 110812.16.23

Содержание R132

Страница 1: ...80446339 Revision B October 2012 Save These Instructions Contact Cooled Rotary Screw Air Compressor Product Information R37 160 110812 16 23 PRINT LANGUAGE ENGLISH SPANISH FRENCH PORTUGUESE...

Страница 2: ...ice warnings 15 Initial check trips 15 Trips 15 OPERATING INSTRUCTIONS FOR FIXED SPEED FS 16 SG Controller Controls Fixed Speed 16 Display screen 16 Current status 17 Main menu 18 Operator setpoints 1...

Страница 3: ...ks are fully engaged on both sides Alternatively a special lifting frame can be used to enable a crane or hoist to move the compressor Use only marked lifting points Once the packaging and pallet are...

Страница 4: ...volume is sufficient 1 2 4 5 6 7 8 Discharge piping should be at least as large as the discharge connection of the compressor All piping and fittings should be suitably rated for the discharge pressur...

Страница 5: ...agram furnished separately from this manual NOTICE Main and fan motor insulation shall be tested by a qualified electrician prior to initial start up or following an extended shutdown period in cold a...

Страница 6: ...surface Perhaps the largest contributor to scale formation is the precipitation of calcium carbonate out of the water This is dependent on temperature and pH level The higher the pH value the greater...

Страница 7: ...the system is enhanced by a control logic that varies the cooling blower speed dependent on the intake and discharge temperatures and hence controls the injection temperature even closer while saving...

Страница 8: ...by a local or remote stop a shutdown due to a trip or an emergency stop All of the above conditions will cause the compressor to stop immediately except the local or remote stop A local or remote stop...

Страница 9: ...ow the display screen are defined by the words immediately above them in the bottom line of the screen Each function such as MAIN MENU STATUS etc is described in appropriate sections in this manual Di...

Страница 10: ...when the ENERGY STATUS screen is displayed pressing the STATUS button will toggle the display to the CURRENT STATUS screen The ENERGY STATUS screen displays the following items ENERGY STATUS Items Ave...

Страница 11: ...ser adjustable variables in the controller logic that can be set using the OPERATOR SETPOINTS screen shown here The name and value of each of the setpoints listed can be seen on the screen by moving t...

Страница 12: ...is pressure The range for this setpoint will be the automatic stop pressure to automatic stop pressure 10 psi Blowdown Mode Two stage compressors will always blowdown when signalled to stop If this mo...

Страница 13: ...the day that a scheduled start will take place The selections are Sunday Monday Tuesday Wednesday Thursday Friday Saturday Daily Su Sa Weekdays M F or Weekends This option setpoint will work with the...

Страница 14: ...f the compressor for the time period that was started by selecting the reset averaging setpoint This is calculated by multiplying the kW hours of the motor and the blower by the energy rate ENERGY SAV...

Страница 15: ...ecognized as missing or broken VSD FAULT The VSD fault is read from the drive The controller will read the status menu of the variable speed drive If a fault condition is returned in the status inform...

Страница 16: ...ultiple functions relating to the right half of the display screen When lists are presented the buttons are used to move up or down through the items on the list The small arrow s displayed in the upp...

Страница 17: ...r IN PR Coolant Filter OUT PR Inlet Vacuum Inlet Filter Total Hours Loaded Hours Software Title and Version Figure 16 Operator Panel Flow Diagram The controller automatically returns the display to th...

Страница 18: ...onal compressor hardware and the correct Option Module to plug into the controller Descriptions of the options operations can be found later in this section The name and value of each of the following...

Страница 19: ...s each of the Trip messages for the last 15 Trips experienced by the compressor It also gives access to displaying the compressor operating conditions that existed at the time of each Trip The first o...

Страница 20: ...exceptions to this are explained in the Trip descriptions The possible Trip messages are as follows CHECK MOTOR ROTATION This will occur if the compressor is started and the compressor has incorrect r...

Страница 21: ...he main electrical isolation switch Stopping the compressor in an emergency If the compressor has to be stopped in an emergency DEPRESS THE EMERGENCY STOP BUTTON 1 This will over ride the normal unloa...

Страница 22: ...d logged in the event log Table 9 Command Keys Icon Name Function None Load Puts the compressor into the selected mode of operation Unit will load if the pressure conditions are right Unload Puts the...

Страница 23: ...Indicates that there are more pages available by navigating left Accessing parameters After the desired page is selected the page s parameters can be selected by using the DOWN key The cursor will mov...

Страница 24: ...ble from the General Settings folder Run Hours indicate the number of hours the compressor has been running NOTICE The online and offline set points can be selected and modified on this page All other...

Страница 25: ...perator Options Selection Min Max Def Step Unit Installed option required Enable Auto Restart ON OFF Off No Auto Restart Time 2 60 10 1 min No Auto Restart Delay 0 60 0 1 sec No Comm Control ON OFF Of...

Страница 26: ...See the following lists for details about messages in each type of event Warning Events List Change Inlet Filter Will occur if 1AVPT is greater than 0 7 psi vacuum or 1 3 psi vacuum if the high dust...

Страница 27: ...709 about 5 C However the warning will still be displayed Dryer High Pressure On compressors with the integrated dryer this will occur if the dryer high pressure switch opens while the dryer is runni...

Страница 28: ...r if the sensor zero value is 10 of its scale This will only occur when a sensor is calibrated Start Inhibit List High Airend Discharge Temperature This will occur if 2ATT is greater than 95 of 228 F...

Страница 29: ...ian Chinese simplified Croatian Czech Danish Dutch Estonian Finish French German Greek Hungarian Italian Indonesian Korean Latvian Lithuanian Maltese Norwegian Polish Portuguese Romanian Russian Slova...

Страница 30: ...y Confirm New Time and Date Used to verify that changes to selections are desired An x must appear in the checkbox before any changes will take affect The controller will continue to display any chang...

Страница 31: ...Discard any changes made to the Ethernet settings Status folder NOTICE All information on these pages is read only Pages 1 3 Analog Inputs Figure 50 Analog Inputs The following inputs are displayed i...

Страница 32: ...ues in this folder This folder is used for setting parameters that are specific to that compressor and displaying software information for the controller Page 1 Password Figure 55 Password Table 21 Pa...

Страница 33: ...lways centered on the gauge This is the pressure that the compressor is trying to maintain Automatic Stop Setpoint is indicated in the white box and by the white arrow which is always right of center...

Страница 34: ...e Injected Coolant Temperature Aftercooler Discharge Temperature Separator Pressure Drop Coolant Filter Pressure Drop Inlet Vacuum Remote Pressure optional Aftercooler Discharge Pressure integrated dr...

Страница 35: ...perature is only adjustable if the low ambient factory set point is on A value of 0 will disable the lead lag cycle time feature Pages 6 7 Sensor Calibration Figure 63 Sensor Calibration Sensor calibr...

Страница 36: ...occur if the compressor is running and 2ATT is greater than 221 F 97 of 228 or the compressor is in idle mode 3 3 7 1 and 2ATT is greater than 184 F This warning will normally have a 5 second delay h...

Страница 37: ...en a sensor is recognized as missing or broken The sensors affected by this trip are 4APT 3APT 2APT 1AVPT 5CPT 6CPT and 2ATT The sensor should be displayed along with the sensor failure message The se...

Страница 38: ...168 psi Start Inhibit List High Airend Discharge Temperature This will occur if 2ATT is greater than 95 of 228 F High Sump Pressure This will occur if the sump pressure 3APT is 25 psi or higher than...

Страница 39: ...after the service has been performed General settings folder NOTICE All parameters in this folder are adjustable Page 1 Language Selection Figure 70 Language Selection Language is selectable from the...

Страница 40: ...elect Home Page Used to select the Home Page within the selected Home folder Page 4 5 Time Date Settings Figure 73 Time Date Settings All items are adjustable The following settings are displayed in t...

Страница 41: ...ed this setpoint sets the IP address of the controller IP Address Actual This will match the IP address setting when DHCP is not enabled If DHCP is enabled this will display the address assigned to th...

Страница 42: ...er Feedback is TRUE when its input is in the high state where as E Stop is TRUE when its input is at 0Vdc The following are displayed in this section Emergency Stop Main Motor Overload Fan Motor Overl...

Страница 43: ...able the password time feature Timeout Delay This timeout along with the password timeout enable allows the user to set an adjustable amount of time to require a valid password to be re entered Once t...

Страница 44: ...page highlighting this button and hitting enter will cause the controller to clear all history of maximum values and begin recording them again The password must be entered in order to use this reset...

Страница 45: ...110812 16 23...

Страница 46: ...110812 16 23...

Страница 47: ...writing to the Company in said period whereupon the Company shall at its option correct such nonconformity by suitable repair to such equipment or furnish a replacement part F O B point of shipment p...

Страница 48: ...ingersollrandproducts com 2012 Ingersoll Rand plc 110812 16 23...

Отзывы: