background image

OPERATOR’S MANUAL

PM20R-X-X-A02

RELEASED:

4-30-04

REVISED:

       11

-

15-

10

(REV. 0

4

)

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

2” DIAPHRAGM PUMP

1:1 RATIO (METALLIC)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

Refer to Model Description Chart to match the pump material options.
637369 for Air Section repair (see page 6).
637309-XX for Fluid Section repair (see page 4). NOTE: This kit also

contains several air motor seals which will need to be replaced.

637374 Major Air Valve Assembly (see page 7).

PUMP DATA

Models

See Model Description Chart for ‘‘-XXX’’.

. . . . . . . . . . . .

Pump Type

Metallic Air Operated Double Diaphragm

. . . . . . . . .

Material

See Model Description Chart.

. . . . . . . . . . . .

Weight

183.6 lbs (83.3 kgs)

. . . . . . . . . . . . . . . . . . . . . . . . .

Maximum Air Inlet Pressure

120 p.s.i.g. (8.3 bar)

. . . . . . . . .

Maximum Material Inlet Pressure

10 p.s.i.g. (0.69 bar)

. . . . .

Maximum Outlet Pressure

120 p.s.i.g. (8.3 bar)

. . . . . . . . . .

Maximum Flow Rate

(

flooded inlet

)

170 g.p.m. (644 l.p.m.)

. . . .

Displacement / Cycle @ 100 p.s.i.g.

1.4 gal. (5.3 lit.)

. . .

Maximum Particle Size

1/4” dia. (6.4 mm)

. . . . . . . . . . . .

Maximum Temperature Limits

E.P.R.

-60

_

to 280

_

F (-51

_

to 138

_

C)

. . . . . . . . . . . . . . . . .

Nitrile

10

_

to 180

_

F (-12

_

to 82

_

C)

. . . . . . . . . . . . . . . . .

Polypropylene

35

_

to 1

7

5

_

F (2

_

to

 79

_

C)

. . . . . . . . . . .

Santoprene

R

-40

_

to 225

_

F (-40

_

to 107

_

C)

. . . . . . . . . . . .

PTFE

0

_

to 225

_

F (4

_

to 107

_

C)

. . . . . . . . . . 4

Dimensional Data

see page 8.

. . . . . . . . . . . . . . . .

Mounting Dimension

9-1/16’’ x 10-1/16’’ (230 mm x 256 mm)

. . . .

Noise Level

@ 70 p.s.i., 60 c.p.m.

{

85.0 db(A)

|

. . . .



Tested with 67263 muffler assembly installed.



The pump sound pressure levels published here have been updated to an Equivalent
Continuous Sound Level (L

Aeq

) to meet the intent of ANSI S1.13-1971, CAGI-PNEU-

ROP S5.1 using four microphone locations.

NOTICE: All possible options are shown in the chart, however, certain
combinations may not be recommended, consult a representative or the
factory if you have questions concerning availability

.

2” DIAPHRAGM PUMP

PM20R-CSS-XXX-A02

Figure 1

MODEL DESCRIPTION CHART

PM20 R - C S S - X X X - A02

PM20R - CSS - X X X - A02

637309 - X X

Diaphragm

Ball

FLUID SECTION SERVICE KIT SELECTION

EXAMPLE: MODEL # PM20R-CSS-SAA-A02
FLUID SECTION SERVICE KIT # 637309-AA

SEAT MATERIAL

A - Santoprene
S - 316 Stainless Steel

DIAPHRAGM MATERIAL

A - Santoprene
M - Medical Grade Santoprene
T - PTFE / Santoprene

HARDWARE MATERIAL

S - Stainless Steel

FLUID CAPS & MANIFOLD MATERIAL

S - Stainless Steel

PORT

C - Tri-Clamp

CENTER SECTION MATERIAL

R - Polypropylene

BALL MATERIAL

A - Santoprene
T - PTFE

Содержание PM20R A02 Series

Страница 1: ... mm Maximum Temperature Limits E P R 60_to280_F 51_to 138_C Nitrile 10_ to 180_ F 12_ to 82_ C Polypropylene 35_ to 175_ F 2_ to 79_ C SantopreneR 40_to225_F 40_to 107_C PTFE 0_ to 225_ F 4_ to 107_ C 4 Dimensional Data see page 8 Mounting Dimension 9 1 16 x 10 1 16 230 mm x 256 mm Noise Level 70 p s i 60 c p m 85 0 db A Tested with 67263 muffler assembly installed The pump sound pressure levels p...

Страница 2: ...mage Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements S Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing alumi numwettedpartscannotbeusedwith III Trichloroethane Me thy...

Страница 3: ...e surface to insure against damage by vibration PARTS AND SERVICE KITS Refertothepartviewsanddescriptionsasprovidedonpage4through7 for parts identification and Service Kit information S Certain ARO Smart Parts are indicated which should be available for fast repair and reduction of down time S Service kits are divided to service two separate diaphragm pump functions 1 AIR SECTION 2 FLUID SECTION T...

Страница 4: ...X 93358 4 4 T XXM 637309 XM 94329 M 2 MSP XXT 637309 XT 94355 T 94330 A 2 T SP COMMON PARTS Item Description size Qty Part No Mtl Item Description size Qty Part No Mtl 1 Rod 1 94358 C 5 Backup Washer 2 94357 2 SS 6 Diaphragm Washer 2 94357 2 SS 9 Washer 2 93065 SS 14 Screw 5 8 18 x 2 1 2 2 Y5 111 T SS 15 Fluid Cap 2 95570 1 SS 26 Screw M10 x 1 5 6g x 35 mm 8 94409 2 SS 27 Screw M10 x 1 5 6g x 45 m...

Страница 5: ... petroleum grease k Apply Lubriplate FML 2 grease to all O rings U Cups mating parts z Used with PM20R CSS SXX A02 models only x Apply Loctite 242 to threads at assembly s Apply PTFE tape to threads at assembly COLOR CODE DIAPHRAGM BALL MATERIAL COLOR COLOR Santoprene Tan Tan Santoprene Green N A Backup PTFE White White 8 6 4 1 2 3 5 7 Torque Sequence 126 s 29 19 z k 21 22 26 G 181 175 k 14 Diaphr...

Страница 6: ...ice is continued from Fluid Section repair S Inspect and replace old parts with new parts as necessary Look for deep scratches on surfaces and nicks or cuts in O rings S Take precautions to prevent cutting O rings upon installation S Lubricate O rings with Lubriplate FML 2 grease S Do not over tighten fasteners refer to torque specification block on view S Re torque fasteners following restart S S...

Страница 7: ... grease to O rings U Cups mating parts 136 137 k 139 k 111 138 k 105 135 133 134 101 103 174 k 121 118 173 k 169 k 172 k 171 k 170 167 k 173 121 k 174 118 166 k 132 k 147 k 146 k 199 k 141 k 140 232 k 200 k 232 k 233 176 k PILOT VALVE PART GROUP MAJOR VALVE A 637374 Replacement Major Valve Service Assembly is available separately which includes the following 105 4 107 2 111 132 135 136 137 138 139...

Страница 8: ... be sized at leastas large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non col lapsing type capable of pulling a high vacuum S Check all joints on the inlet manifolds and suction connections These must be air tight S Inspectthepumpforsolidobjectsloggedinthediaphragmchamber or the seat area DIMENSIONAL DATA Dimensions sho...

Отзывы: