background image

Table 2:  Specifications

Models

Operating

Mode

Air System

Rated Performance (at rated pressure/volume)

Net Weight **

Rated

Operating

Pressure

Air Consumption

(at rated pressure

and load)

Full Drum

Line Pull

Full Drum

Line Speed

Max Stall Pull, 1st

Layer

Force

Limit

Factor

Maximum

Freeboard

scfm

cu.m/

min

lbs

kgs

fpm

m/min

lbs

kgs

inch

mm

lbs

kgs

FA2.5i-

MR

Utility

90 psig (630

kPa/6.3 bar)

700

20

5,000

2,273

132

40

10,500

4,763

N/A

0.5

13

1,190

540

Man Rider

3,180

1,445

173

53

1.3

32

1,265

574

FA2.5i-

MR-CE

Utility

70 psig (480

kPa/4.8 bar)

5,000

2,273

98

30

1.6

1,115

506

Man Rider

3,180

1,445

135

41

6,300

2,858

N/A

1,290

585

FA5i-

MR

Utility

90 psig (630

kPa/6.3 bar)

11,000

5,000

54

16

29,000

13,154

0.5

13

1,895

860

Man Rider

6,875

3,124

75

23

1.5

38

2,000

907

FA5i-

MR-CE

Utility

80 psig (550

kPa/5.5 bar)

11,000

5,000

52

16

25,900

11,748

1.6

1.6

40

1,985

900

Man Rider

6,875

3,124

72

22

15,200

6,895

N/A

2,025

919

** Weight of standard winch without wire rope.

Table 3:  Specifications

Models

Air Motor Pipe

Inlet Size

Minimum Air System

Hose Size (inside

diameter)

Drum

Barrel

Diameter

Drum

Flange Diameter

Recommended Wire

Rope Size

Sound

Pressure

Level

Sound

Power

Level

Maximum

Foundation Anchor

Shear Force at One

Capscrew

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

dBA

dBA

lbs

N

FA2.5i-

MR &

FA2.5i-

MR-CE

1.25

32

1.50

38

10.75

273

19

483

5/8

16

97

109

2,210

9,830

FA5i-MR

& FA5i-

MR-CE

1.25

32

1.50

38

15

381

27

686

3/4

20

97

109

4,850

21,570

Sound measurements have been made in accordance with ISO 11201, ISO 3744-3746

and ISO 4871 test specifications for sound from pneumatic equipment. Readings

shown are based on the average noise level of each winch configuration,

proportionate to the utilized time in a regular cycle.

Lpc (Peak Sound Pressure) does not exceed 130 dB. Performance based on 90 psig

(6.3 bar/630 kPa) operating pressure.

Table 4:  Available Drum Lengths

Models

Drum Lengths

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

FA2.5i-

MR/

FA2.5i-

MR-CE

8

203

12

305

16

406

20

508

24*

610*

30

762

36

915

40** 1016**

42**

1067** 50**

1270**

FA5i-MR/

FA5i-MR-

CE

---

---

* Standard Length
** Special, contact factory
Refer to sales literature for winch drum wire rope storage capacities.

NOTICE

All -E winch models are manufactured to previous European Machinery

directives. Refer to Data (Name) Plate on winch to determine model. If winch

is a custom build also refer to the Declaration of Conformity for serial

number break.

n

Traceability

Load bearing parts are documented to provide traceability. Documentation includes

chemical and physical properties of raw material, heat treating, hardening, tensile

and charpy tests as required for the part.

Units with M1M2 or M3 in the model code have traceable load bearing

components.

M1 – Material Traceability certificates according to EN 10204 (Ex DIN 50049) 2.2 on

load bearing parts. Conformity documents affirm (by the manufacturer) that parts

are in compliance with requirements of the order, based on non-specific inspection

and testing (i.e. results are typical material properties for these parts).

M2 – Material Traceability certificates according to EN 10204 (Ex DIN 50049) 3.1b on

load bearing parts. Conformity documents affirm (by a department independent of

the manufacturing department) that actual parts are in compliance with

requirements of the order, based on specific inspection and testing (i.e. results are

actual material properties for these parts).

M3 – Material Traceability certificates according to EN 10204 (Ex DIN 50049) 3.1b on

load bearing parts. Conformity documents affirm (by a department independent of

the manufacturing department) that the actual parts used in the product are in

compliance with the order, based on specific inspection and testing (i.e. results are

actual material properties for these parts in a finished, as delivered condition).

Components with part numbers ending in CH are charpy parts for use under extreme

cold conditions. Traceability requirements must be stated when reordering these

parts for continued certification.

n

ATEX

Refer to labeling on product, located near or on data (name) plate, for specific ATEX

designation. Product not marked as such, are not suitable for use in any potentially

explosive atmosphere (ATEX). Refer to Product Safety and Maintenance Information

Manuals for further explanation.

II 2 GD c IIB 200°C X

(Dwg. MHP2584)

4

Form MHD56435 Edition 6

Содержание FA2.5-MR-CE

Страница 1: ...Product Information Force 5i Winches Models FA2 5i MR FA2 5i MR CE FA5i MR and FA5i MR CE Dwg MHP2669 Save These Instructions R Form MHD56435 Edition 6 January 2014 45899770 2014 Ingersoll Rand...

Страница 2: ...ary reduction gear assembly Output from the planetary reduction gear assembly is connected to the wire rope drum through the output shaft The disc brake assembly consisting of friction plates splined...

Страница 3: ...ing ABS N5 Det Norske Veritas DNV P Marine 812 Grade Corrosion Preventative Finish Q Adjustable Accu Spool P1 Marine812 XGradeCorrosionPreventativeFinish W1 ABS witness test S Limit Switch upper and l...

Страница 4: ...R CE Standard Length Special contact factory Refer to sales literature for winch drum wire rope storage capacities NOTICE All E winch models are manufactured to previous European Machinery directives...

Страница 5: ...d applications order the U option or contact factory prior to operation n Wire Rope Selection Consult a reputable wire rope manufacturer or distributor for assistance in selecting the appropriate type...

Страница 6: ...oducts data name plate to see if this applies n Moisture in Air Lines Moisture that reaches the air motor through air supply lines is a primary factor in determining the length of time between service...

Страница 7: ...Port The winch control throttle valve is spring loaded full flow air and mounts to the motor rotary housing To operate control valve place palm of hand on control knob and wrap fingers around flange o...

Страница 8: ...haul in position 1 If overload valve activates reset overload valve Winch is ready for normal operation 2 If winch lifts load lower load Turn adjustment screw counterclockwise in 1 4 turn increments...

Страница 9: ...e Test shut off valve to ensure proper operation and free movement 5 Guards Verify wire rope does not contact guard during winch operation and that guards are secure and undamaged 6 Winch Visually ins...

Страница 10: ...elow freezing wait long enough at the end of shift for water to separate from oil but not long enough for it to freeze Drain water then refill to level plug located on side of motor housing If desired...

Страница 11: ...g MHP2686 Air Out Regulator Lubricator Air In Filter A B C D E Dwg MHP0191 Lift Slider Handle UP to Unlock Exhaust Port 1 1 2 NPT Air Inlet Port 1 1 4 NPT Brake Release Port 1 4 NPT Payout Haul In A C...

Страница 12: ...t Cap Drain Plug Level Plug A Fill Cap Dwg MHP2126 A B C E D Fill Plug Position Drum Reduction Gear Assembly Level Plug Position Inboard Upright Dwg MHP0140 Dwg MHP1348 To Brake Threaded Ports A B Dwg...

Страница 13: ...ency Stop Button ON Button Function Levers Pendant Handle A B C D Dwg MHP1892 A B C D Dwg 45899051 Dwg MHP2688 A C B D Emergency Lowering Inlet Rotate handle to use in normal condition FRL Main Air Su...

Страница 14: ...t direkt vas u nosac jumiem LV Kuriems taikoma i deklaracija atitinka ios direktyvos nuostatas NL waarop deze verklaring betrekking heeft overeenkomt met de bepalingen van directieven NO som denne erk...

Страница 15: ...direkt vas u nosac jumiem LV Kuriems taikoma i deklaracija atitinka ios direktyvos nuostatas NL waarop deze verklaring betrekking heeft overeenkomt met de bepalingen van directieven NO som denne erkl...

Страница 16: ...R www ingersollrandproducts com...

Отзывы: