0.0 SAFETY AND WARNINGS
0.1 safety instructions
0.2 safety precautions
0.3 decals
1.0 RECEIPT OF EQUIPMENT
1.1
inspection
1.2
unpacking and handling
1.3
tools
2.0 INSTALLATION
2.1
ventilation
2.2
foundation requirements
2.3
piping
2.4
electrical installation
2.5
outdoor sheltered installation
3.0 INTELLISYS
3.1
emergency stop switch
3.2
power on light
3.3
power indicator light
3.4
push buttons
3.5
set point procedure
3.6
warnings
3.7
alarms
4.0 SYSTEMS
4.1
general systems
4.2
aircooled compressors
4.3
coolant system
4.4
compressed air system
4.5
coolant/air separation system
4.6
electrical system
4.7
compressor control system
4.8
options
5.0 MAINTENANCE
5.1
maintenance schedule
5.2
maintenance records
5.3
maintenance procedures
5.4
inlet air filter
5.5
coolant filter
5.6
coolant
5.7
separator tank scavenge orifice/screen
5.8
coolant separator element
5.9
cooler cores
5.10 drive motor lubrication
5.11 long term storage
2
TABLE OF CONTENTS
5.12 coolant/lubricant changeout
5.13 intellisys removal
5.14 coolant hoses
5.15 airend discharge hose
5.16 fluid and vibration monitoring
5.17 coolant sampling procedure
6.0 TROUBLE SHOOTING
7.0 REFERENCE DRAWINGS
7.1
electrical schematic - full voltage
7.2
electrical schematic - star delta
7.3
foundation plan - air cooled
7.4
foundation plan - water cooled
7.5
foundation plan - outdoor mod
7.6
basic flow schematic - air cooled
7.7 basic flow schematic - water cooled
7.8
typical system flow diagrams
8.0
WATER QUALITY RECOMMENDATIONS
9.0
MAINTENANCE RECORD
GENERAL INFORMATION
Weight:
See foundation plan, Section 7.0
Cooling Air Flow:
See foundation plan, Section 7.0
Ambient Temperature Limit:
35°F to 115°F (2°C to 46°C)
Coolant:
Factory Filled SSR Ultra Coolant
Coolant Change:
8000 hours or two years, whichever
comes first
Coolant Capacity:
50-60 hp 5.0 gal. (18.9 liters)
37-45 kw 5.0 gal. (18.9 liters)
75-100 hp 9.0 gal. (34.2 liters)
55-75 kw 9.0 gal. (34.2 liters)
Discharge Temperature Limit:
228°F (109°C)
Power Inlet Wiring:
Recommended conduit: metallic
flexible Greenfield, or equivalent,
Tools:
U.S. Standard and metric are required
to perform maintenance
Содержание EP 60
Страница 18: ...16 FIGURE 2 5 1 TYPICAL OUTDOOR SHELTERED INSTALLATION ...
Страница 31: ...29 NOTES ...
Страница 44: ...42 7 0 REFERENCE DRAWINGS 7 1 ELECTRICAL SCHEMATIC FULL VOLTAGE 39899794 REV 02 ...
Страница 45: ...43 7 2 ELECTRICAL SCHEMATIC STAR DELTA 39899786 REV 02 ...
Страница 46: ...44 7 3 FOUNDATION PLAN AIR COOLED 39894472 REV 03 ...
Страница 47: ...45 7 4 FOUNDATION PLAN WATER COOLED 39907894 REV 03 ...
Страница 48: ...46 7 5 FOUNDATION PLAN OUTDOOR MOD 39907886 REV 03 ...
Страница 49: ...7 6 BASIC FLOW SCHEMATIC AIR COOLED 39899828 REV 02 47 ...
Страница 50: ...48 7 7 BASIC FLOW SCHEMATIC WATER COOLED 39899836 REV 02 ...
Страница 51: ...49 7 8 TYPICAL SYSTEM FLOW DIAGRAMS TYPICAL SYSTEM FLOW DIAGRAM ...
Страница 52: ...50 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 53: ...51 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 54: ...52 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 55: ...53 7 8 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 59: ...57 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY 9 0 MAINTENANCE RECORD ...
Страница 60: ...DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD 58 ...
Страница 61: ...59 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Страница 62: ...60 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...