44
TROUBLE SHOOTING CHART (Continued)
TROUBLE
CAUSE &/OR DISPLAY
WHAT TO DO
High coolant
Excessive coolant level.
— Check level, lower if necessary by
consumption/coolant
draining.
in air system
Plugged separator element.
— Check separator pressure drop.
Separator element leak.
— Check separator pressure drop. If low,
replace element.
Plugged separator scavenge orifice/
— Remove and inspect orifice/screen.
screen.
Clean if required.
Compressor operating at low pressure
— Operate at rated pressure.
(75 psig or below).
— Reduce system load.
Coolant system leak.
— Inspect and repair leaks.
Water in Air System
Defective moisture separator/drain trap
— Inspect and clean if required. Replace
separator/trap if defective.
Trap drain or drain piping plugged.
— Inspect and clean.
Aftercooler core dirty.
— Inspect and clean.
Enclosure panels not in place.
— Install enclosure panels.
Drain line/drip leg incorrectly installed.
— Slope drain line away from trap. Install
drip leg.
No refrigerated or desiccant dryer in
— Contact local Ingersoll-Rand
air system.
Distributor or Air Center.
V-belts slipping.
— Adjust belt tension or replace belts.
Excessive noise level
Compressor defective. (Bearing
— Contact authorized Distributor or Air
failure or rotor contact.)
Center immediately, do not operate
unit.
Enclosure panels not in place.
— Install enclosure panels.
Loose component mounting.
— Inspect and tighten.
Excessive vibration
Loose components
— Inspect and tighten.
Motor or compressor bearing failure.
— Contact authorized Distributor or Air
Center immediately, do not operate
unit.
External sources.
— Inspect area for other equipment.
Shaft Seal leak
Defective shaft seal.
— Replace per this manual or contact
authorized Distributor or Air Center
Black residue on belt guards
V-belts loose.
— Adjust belt tension.
Sheaves mis-aligned.
— Align sheaves.
Excessive belt wear
— Replace belts.
Pressure relief valve opens
Compressor operating over pressure.
— Adjust Intellisys set points.
Defective valve.
— Replace valve.
Содержание EP 20 SE
Страница 18: ...16 FIGURE 2 5 1 TYPICAL OUTDOOR SHELTERED INSTALLATION ...
Страница 48: ...46 8 0 REFERENCE DRAWINGS 8 1 ELECTRICAL SCHEMATIC FULL VOLTAGE 39838388 REV 01 ...
Страница 49: ...47 8 2 ELECTRICAL SCHEMATIC STAR DELTA 39851985 REV 01 ...
Страница 50: ...48 8 3 ELECTRICAL SCHEMATIC FULL VOLTAGE REMOTE MOUNTED STARTER 39845029 REV 01 ...
Страница 51: ...49 NOTES ...
Страница 52: ...50 8 4 FOUNDATION PLAN ENCLOSED Continued 39838750 REV 02 ...
Страница 53: ...51 8 4 FOUNDATION PLAN ENCLOSED 39838750 REV 02 ...
Страница 54: ...52 8 4 FOUNDATION PLAN UNENCLOSED Continued 39848171 REV 02 ...
Страница 55: ...53 8 4 FOUNDATION PLAN UNENCLOSED 39848171 REV 02 ...
Страница 56: ...54 8 6 FOUNDATION PLAN OUTDOOR MODIFICATION Continued 39848189 REV 02 ...
Страница 57: ...55 8 6 FOUNDATION PLAN OUTDOOR MODIFICATION 39848189 REV 02 ...
Страница 62: ...60 8 11 TYPICAL SYSTEM FLOW DIAGRAMS TYPICAL SYSTEM FLOW DIAGRAM ...
Страница 63: ...61 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 64: ...62 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 65: ...63 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 66: ...64 8 11 TYPICAL SYSTEM FLOW DIAGRAMS ...
Страница 67: ...65 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY 9 0 MAINTENANCE RECORD ...
Страница 68: ...66 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Страница 69: ...67 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...
Страница 70: ...68 DATE RUN TIME WORK DONE QTY UNIT WORK HOURS MEASURE BY MAINTENANCE RECORD ...