Nix Product Manual |
Product Description
INGENIA | 01/22/2019
13
Communications
USB
µUSB (2.0) connector. The board can be supplied from USB for configuration purposes
but will not power the motor.
Serial
RS485 full-duplex (compatible with RS422), non-isolated. 120 Ω termination on the RX
line (v 1.1.0) and on the TX line (v 1.2.0).
CANopen
Available. Non-isolated. Includes jumper to enable 120 Ω termination.
CiA-301, CiA-305 and CiA-402 compliant.
EtherCAT
Available.
Environmental and mechanical specifications
Ambient air
temperature
•
-40 ºC to +50 ºC full current (Operating). If the Nix is mounted on a heatsink plate
the range can be extended up to 85ºC heatsink temperature.
•
+50 ºC to +100 ºC current derating (operating)
•
-40 ºC to +125 ºC (storage)
Maximum
humidity
5% - 85% (non-condensing)
Dimensions
75 x 60 x 14 mm
Weight (exc.
mating
connectors)
86 g
4.3
Hardware revisions
1.0.0
November 2015
First product demo.
Hardware revision*
Description and changes