39
XtrapulsCD1-pm
– Installation manual
Chapter 5 - Appendix
2
– ADJUSTMENT TO VARIOUS RESOLVER TYPES
For other resolver connections than the Infranor standard (chapter 3, section 3), see following wiring diagram of
the
X1
connector as well as the manufacturer's diagram:
For the use of
resolvers
with
transformation ratios
out of the range 0.3 to 0.5, the adjustment must be factory
set.
NOTE
When using resolvers with a number of pole pairs N > 1, all speed values displayed in the drive are equal to N
times the motor rotation speed.
3 - USE OF THE "AOK" OUTPUT
The "AOK" output MUST be used on a potential free relay in order to allow the connection of the power supply
(see Chapter 4, section 1: Connection diagrams).
The correct drive operation requires this connection logic. Switching on the power supply before initializing by
means of the 24 VDC auxiliary supply will hinder the operation. It will then be necessary to proceed according to
the instructions contained in this manual.