Chapter 7 – Troubleshooting
1.10 - FOLLOWING ERROR
The FOLLOWING ERROR fault corresponds to a following error of the speed loop.
¾
Check that the load is actually adjusted to motor and amplifier types.
¾
Reduce the accelerations/decelerations.
¾
Check that the axis is not positioned on a mechanical stop.
¾
Check that the value of the parameter
Speed following error threshold
is compatible with the operation
cycle. If necessary, increase the value of this parameter.
2 - OPERATING PROBLEMS
2.1 - MOTOR DOES NOT MOVE
¾
Check that the amplifier is on (24 VDC auxiliary supply on).
¾
Check that the power supply is on.
¾
Check the motor connection.
¾
Check the logic wiring of the signals FC+, FC- and ENABLE (
2.2 - MOTOR SUPPLIED, BUT NOT TORQUE
¾
Check that the
Maximum current
and
Rated current
parameters have no zero value.
¾
Check that the amplifier is not operating in torque mode (CI command active on X4) with zero input command.
2.3 - SHAFT LOCKED, ERATIC OSCILLATIONS OR ROTATION AT MAXIMUM SPEED
¾
Check the resolver wiring on the X1 connector and the mechanical mounting of the resolver on the motor.
¾
Check the proper motor choice in the
MOTOR LIST
module.
¾
Check the value of the
Motor parameters
in the
Advanced Functions
menu and execute the
AUTO-
PHASING
command again, with unloaded motor, if necessary (see
2.4 - DISCONTINUOUS MOTOR ROTATION WITH ZERO TORQUE POSITIONS
¾
Check the connection of the 3 phase cables between motor and amplifier.
2.5 - MOTOR DRIFT WITH ANALOG INPUT COMMAND AT ZERO SPEED
¾
Check that the input command wiring between the controller and the amplifier corresponds to the
recommendations of chapter 4 (CV- at diff. low of the NC and 0 Volt cable).
¾
Check the offset compensation and, if necessary, execute the
Offset compensation
command.
2.6 - LOUD CRACKLING NOISE IN THE MOTOR AT STANDSTILL
¾
Check that the motor-amplifier-controller ground connections correspond to the
¾
Check that the speed input command wiring between controller and amplifier correspond to the
recommendations of chapter 4 and check the shield connection of the resolver cables on motor and amplifier
side.