35
CD1-a
Chapter 6 - Commissioning
In case of loud noise in the motor at standstill and when running, check the rigidity of the transmission
between motor and load (backlashes and elasticities in gears and couplings). If necessary, start the
Auto-
tuning
procedure while selecting a
lower
bandwidth. If the problem remains, renew the
Auto-tuning
while
activating
the
antiresonance filter
.
♦
Start the
Offset compensation
function or start the offset compensation by means of the
Offset
push- button
on the amplifier front panel.
♦
Check that the motor is correctly running in both directions in mode
Digital speed input command
. If
necessary, readjust the speed regulator parameters by means of the
Stability
button.
3.3 - SPEED LOOP ADJUSTMENT WITH VERTICAL LOAD
Start the
Auto-tuning
procedure with the
motor uncoupled from its mechanical load
in order to initialize the
speed loop gains. Select the
limiting
mode of the I
2
). Then select the speed
regulator (
PI
or
PI
2
). Couple the motor to the load again and move the shaft by means of the digital speed input
command until its maintaining position where
the shaft rotation over one revolution is not dangerous for
operator and machine
.
Then execute the
Auto-tuning
command with the motor
enabled at its maintaining position
(zero speed input
command). In case of loud noise in the motor at standstill and when running, check the rigidity of the transmission
between motor and load (backlashes and elasticities in gears and couplings). If necessary, start the
Auto-tuning
procedure while selecting a
lower
bandwidth. If the problem remains, renew the
Auto-tuning
while activating the
antiresonance filter
.
3.4 - AMPLIFIER PARAMETERS SAVING
Save all parameters in the amplifier EEPROM by means of the function
Parameters saving in the EEPROM
.