Страница 2: ...provements to this document and or product at any time without notice No part of this publication may be reproduced stored in a retrieval system or transmitted in any form of or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Infosystem Automation Corporation Copyright 2004 by Infosystem Technology Corporation Version 1 1 All rights re...

Страница 3: ... AND WIRING 7 3 1 2 POINTS 24V DC INPUT 8 3 2 2 POINTS DC 0 5A DIGITAL OUTPUT 9 4 MODBUS ADDRESS MAPPING 10 4 1 MODBUS HOLDING REGISTER 40001 10 4 2 MODBUS HOLDING REGISTER 40002 10 5 SOFTWARE INSTALLATION 11 6 CONFIGURING THE ETHERNET CONVERTER 14 6 1 CONFIGURING WITH ETHERNET CONVERTER SETUP PROGRAM 14 6 2 CONFIGURING WITH WEB BROWSER 21 APPENDIX 1 COMMAND MODE SUPPORT 25 ...

Страница 4: ... Serial to Ethernet converters are ideal products for any RS 232 422 485 device to connect to an existing Ethernet network With WS 100 and WS 1000 and related products the controlling and monitoring of serial devices can be easily accomplished 1 ...

Страница 5: ...perates as an Ethernet node Serial communication speed is up to 115 2 kbps Supports ARP ICMP TCP UDP IP DHCP HTTP Modbus TCP and 10Base T Ethernet standard Supports Web Based interface for fast configuration without special software also in Command mode for parameters setting by application software Supports Client Server applications Supports Winsock networking programming and optional Virtual se...

Страница 6: ...32 RS 422 R S 485x2 Configurable RS 232x2 Serial Communication Data speed 300 115200 bps Data bits 7 8 Parity None Even Odd Stop bits 1 2 Flow control RTS CTS Data speed 300 115200 bps Data bits 7 8 Parity None Even Odd Stop bits 1 2 Flow control RTS CTS Data speed 300 115200 bps Data bits 7 8 Parity None Even Odd Stop bits 1 2 Flow control RTS CTS Data speed 300 115200 bps Data bits 7 8 Parity No...

Страница 7: ...a rate around 1 Hz when CPU is working normally with the module LINK If ON the Ethernet connection is activated TX If ON the converter is transmitting data to the Ethernet RX If ON the converter is receiving data from Ethernet Switch Description Switch Description OFF Update Firmware SW1 ON Normal Mode SW2 Reserved 4 ...

Страница 8: ... Block This connector offer two UART port connection the pin description is in the following table 9 Pin TB 1 RXD 1 RS 232 Data Input In 2 TXD 1 RS 232 Data Output Out 3 RTS 1 RS 232 Request to Send Out COM1 4 CTS 1 RS 232 Clear to Send In 5 GND RS 232 Ground Power 6 RXD 2 DX RS 232 Data Input RS 422 RS 485 DX In 7 TXD 2 DX RS 232 Data Output RS 422 RS 485 DX Out 8 RTS 2 TX RS 232 Request to Send ...

Страница 9: ...erminal blocks at each side of the Gateway one is 9 Pin terminal block and another is 13 Pin terminal block The 1st pin of the 9 Pin terminal block is neighbor the RJ 45 Ethernet connector and the 1st of the 13 Pin terminal block is neighbor the 2PIN DIP Switch Please see below is the Pin layout of the Gateway Connector and Pin Descriptions RJ 45 It is an 8 Pin RJ 45 Ethernet connector it is conne...

Страница 10: ...Power 6 RXD 4 RS 232 Data Input In 7 TXD 4 RS 232 Data Output Out 8 RTS 4 RS 232 Request to Send Out Com4 9 CTS 4 RS 232 Clear to Send In 10 NC NOT USED NC 11 NC NOT USED NC 12 24GND Gateway Power Ground In Power POWER 13 24 Gateway Power 24V In Power 2 Pin DIP Switch DIP Switch ON Normal Operation This PIN define the Normal Operation Mode or Enter the Firmware update mode when ON enter the Normal...

Страница 11: ...nts Insulation method Photo Coupler Rated input voltage 24V DC Rated input current 7 mA Operating voltage range 21 6V DC 26 4V DC Turn ON state 12VDC 2mA or higher Turn OFF state 4VDC 1mA or lower Input impedance Approx 3 9 KΩ OFF ON 8 msec or less 24VDC Response time ON OFF 8 msec or less 24VDC Common terminal arrangement 12 points common Internal current consumption Max 100 mA type all points ON...

Страница 12: ...21 6VDC 26 4VDC Type NPN Sink Max load current 0 5A pt Leakage current at OFF circuit 0 1 mA or less Max voltage drop at ON circuit 1 5V or less OFF ON 8 msec or less Response time ON OFF 8 msec or less Common terminal arrangement 6 points common Voltage 24VDC 21 6VDC 26 4VDC External power supply Current 100mA International current consumption 100 mA type all points on b Equivalent input circuit ...

Страница 13: ...net Converter is mapped with the Modbus holding register 40001 The following table describes the exact bit mapping for Modbus holding register 40001 Modbus Holding Register Digital Output 40001 DO 1 Bit 0 40001 0 DO 2 Bit 1 40001 1 4 2 Modbus Holding Register 40002 The 12 point digital input of the Ethernet Converter is mapped with the Modbus holding register 40002 The following table describes th...

Страница 14: ... to install the Ethernet I O Utility Program The following screen is displayed Click the OK button to proceed with the next step 5 2 When the following screen is displayed click on the button to continue If you want to use a destination directory different than the default one displayed on the screen just click on Change Directory to locate the desired folder and then click on button to continue 1...

Страница 15: ...5 3 You can change or use the default folder name displayed on the screen and then click on Continue to start copying files 5 4 The following screen shows the copying progress 12 ...

Страница 16: ...5 5 When the installation is completed successfully the following screen came and presses the OK button will terminate the installation program 13 ...

Страница 17: ...ms Ethernet Converter Utility Ethernet_Converter_Setup 6 12 The Ethernet I O Setup window is shown as below 6 13 Click on the button to search all the Ethernet Converter connected in the same subnet using the UDP broadcast protocol When the search is finished the information about all Ethernet Converters found will be listed in the text box as shown below 14 ...

Страница 18: ...6 14 Double click on the desired Ethernet Converters whose configuration is to be modified as shown below Double click on the desired Ethernet Converter 15 ...

Страница 19: ...he parameters of the Ethernet Converter Local IP The IP address of the Ethernet Converter on the TCP IP network The default Local IP address is 192 168 192 250 This address should be unique Ask your network administrator for assistance if in doubt Subnet mask Identifying the network class which the Ethernet Converter belongs to The default Subnet mask is 255 255 255 0 Ask your network administrato...

Страница 20: ...at Ethernet Converter supports only And default communication mode for Ethernet Converter is TCP Server which made Ethernet Converter operate at the Passive or the TCP listen mode to receive TCP connection requests from the remote client device Command Port The Ethernet Converter supports the command mode which user can use to setup the parameters or get the information of the Ethernet Converter w...

Страница 21: ...ure the command port number that the Ethernet I O Setup program used is the same as the Command Port parameter which has been configured in the Ethernet I O setup window To verify this click on Option Command Port as shown below Next when the Command Port window opens input the command port number that is the same as the one which has been set in the setup window and then click on OK 18 ...

Страница 22: ...the Ethernet I O Setup window if password protection is enabled Click on Option Password as shown below When the Password window opens input the correct password that is the same as the one which has been set in the setup window and then click on OK 19 ...

Страница 23: ...6 18 To exit the Ethernet I O Setup program click on Option Exit as shown below 6 19 To show the information about Ethernet I O Setup program click on Help About Ethernet I O Setup as shown below 20 ...

Страница 24: ... the About Ethernet I O Setup window opens view the description shown on the screen and then click on OK 6 2 Configuring With Web Browser 6 21 Start web browser and search the web site using the address 21 ...

Страница 25: ...o the configuration web page Remember to key in the password if authorized entry is required before you click button 6 22 The configuration web page is shown below Please refer to 5 1 for how to setup the related parameters of the Ethernet Converter After setting the parameters press the button to store the modified configuration 22 ...

Страница 26: ...23 ...

Страница 27: ...6 23 Now the Ethernet Converter has been updated and the browser refresh to the login web page again 24 ...

Страница 28: ...eb Server Syntax G MAC address IP Setup Password Return All parameters of the Web Server Example Send out G 0 128 200 255 251 242 192 168 1 100 12345678 Return CG for Cancel or AG All Messages Command S for Web Server Parameters Setting S or s Command Purpose Set the Parameters of the Web Server Syntax S MAC Address IP Setup Password Parameter Value Return A for Accept or C for cancel Example Send...

Страница 29: ...Old MAC Address New MAC Address Factory Password Return AM for accept or CM for cancel Command I for IP setting I Command not for User User should use the S Command for setting IP address Purpose Set the IP address by LAN broadcast Syntax I MAC Address New IP Factory Password Return AI for accept or CI for cancel 26 ...