111
Dimensions
2U series
Dimensions
Without chassis ears & protrusions
Height
88mm
Width
447.4mm
Length
501.2mm
3U series
Dimensions
Without chassis ears & protrusions
Height
130mm
Width
447.4mm
Length
501.2mm
Environment
Humidity
5 to 95% (non condensing
– operating and non-operating)
Temperature
Operating:
a. With Cache Backup Module 0º to 35ºC
b. Without Cache Backup Module 0º to 40ºC
Non-operating: -40º to 60ºC
Altitude
Operating: Sea level to 12,000ft
Packaged: Sea level to 40,000ft
Shock (Half-sine)
Operating: 5G, half-sine, 11ms pulse width
Non-operating: 15G, half-sine, 11ms pulse width
Vibration
(Random)
Operating: 5~500Hz, 0.25Grms,X/Y/Z, 30mins
Non-operating: 5~500Hz, 2.0Grms, X/Y/Z, 30mins
(Sine)
Operating: 5~500Hz, 0.2G, 0.5oct/min, X/Y/Z, 1sweep
Non-operating: 5~500Hz, 1.0G, 0.5oct/min, X/Y/Z, 1sweep
Acoustic Noise
65dBA boundary, 60dBA normal