II. INTRODUCTION 

 
 

Thank you for selecting this uninterruptible power supply (UPS). To choose the SUNLIGHT series as your 
equipment protector was a wise investment. It includes many features to protect your critical equipments. 
 
The  SUNLIGHT series UPS system is connected between  mains and critical loads , such as computer 
systems , telecommunication systems, computerized instruments etc.  

 

The advantages of using UPS: 
 

 

Increased power quality: 

The UPS has its own internal voltage and frequency regulator circuits which ensure that its output is 
maintained within close tolerances independent of voltage and frequency variations on the mains 
power lines. 

 

 

Increased noise rejection: 

By rectifying the input ac power to dc power, and then converting it back to ac, any electrical noise 
that may  present on the input mains supply line is effectively isolated from the UPS output, therefore 
the critical load sees only clean power. 

 

 

Power blackout protection: 

If the mains power fails, the UPS continues to power the critical load from its battery source, leaving 
the load immune from power disturbances. 
 
 

2.1  System Description 
 
Features : 

 

On-line

 technology with pure 

sine wave

 output. 

 

PWM and IGBT technology. 

 

Microprocessor controlled main controller board. 

 

Static (STS) and maintenance by-pass . 

 

LCD (Liquid Crystal Display) display.  

 

Alarm history  ( Memory for max. 64 alarms. ) 

 

Automatic battery testing  (optional). 

 

High quality maintenance-free lead-acid type batteries. 

 

High nonlinear load capacity, special for computers. 

 

Accessories :

 

o

Optional UPS monitoring software (RUPS

 

, RUPSII

 

, UPSILON

 

) SNMP devices,  compatible to 

any operating system. 

o

Remote Monitoring Panel (RMP) available : You can observe  the UPS status and parameters 
without using  a computer at a remote location up to 200 meters away ( via RS485 interface). 

  

o

UPS Port Sharer  available  

 
SUNLIGHT   Series Uninterruptible Power Supplies (UPS) are advanced true On-Line Sine wave devices 
with static transfer switch which provide reliable, regulated, transient-free AC power to sensitive 
equipment.  
 
Since the UPS is a true On-Line system, conditioned power is provided continuously to the connected 
equipments. Unlike standby power systems, the UPS is constantly regulating and filtering the output 
power. When incoming power is interrupted, the UPS protects the computers instantaneously without any 
transfer time. 
 
The SUNLIGHT Series

 

has high non-linear load capability (i.e. Crest Ratio 3:1) and this is suitable for 

powering special loads such as switching power supplies or highly capacitive inputs like computers. 
 
The system's static transfer switch (STS) provides by-pass power as its standby source. During an 
overload condition, the S.T.S will switch the customer's load over to the bypass line with no interruption. 

Содержание SunLight -210

Страница 1: ...USER MANUAL UNINTERRUPTIBLE POWER SUPPLIES 3 Phase Input 1 Phase Output info rise TECHNOLOGIES SunLight 206 6 kVA SunLight 207 7 5 kVA SunLight 210 10 kVA SunLight 215 15 kVA SunLight 220 20 kVA SunL...

Страница 2: ...edure 11 4 2 2 Turn Off Procedure 11 4 3 When Utility Power Is Interrupted 11 4 4 Operator Control Panel 12 4 4 1 Push Buttons 12 4 4 2 First Message Line Of The LCD 12 4 4 3 Second M L ALARMS Of The...

Страница 3: ...ified service personnel The output may be energized when the unit is not connected to a mains supply Risk of electric shock hazardous live parts inside this unit are energized from the battery supply...

Страница 4: ...and maintenance by pass LCD Liquid Crystal Display display Alarm history Memory for max 64 alarms Automatic battery testing optional High quality maintenance free lead acid type batteries High nonline...

Страница 5: ...ransfer Switch static by pass Static transfer switch is an electronically controlled switching circuit checked by main controller board In case of inverter overload or any other faults STS transfers t...

Страница 6: ...Frequency 50 Hz Line Synchronized 1 Output Frequency Tolerance Free Running 0 2 Efficiency 100 Load 85 87 Crest Factor 3 1 Overload capacity 100 125 Load 2 5 min 125 150 Load 10 sec 150 instant by pa...

Страница 7: ...ections Battery Fuse AC Output 220V AC 50Hz 10A max DB9 Port PK1 On Off Switch Main Switch Figure 2 2 1 6 7 5 10 kVA Rear view Figure 2 2 2 Front views Main Switch PK1 On Off Switch UPS Electrical Con...

Страница 8: ...ocation Selection The UPS is designed to be installed in a protected environment The following conditions should be prohibited 1 Blocking the airflow intake and outlet It is recommended to retain 10 c...

Страница 9: ...ioned and secured connect the power cables as described in the following section It is recommended that the UPS should be connected to the line voltage protected by a circuit breaker 1 Before connecti...

Страница 10: ...give the inverter power to the output 3 Disconnect the input power The LINE FAILURE indicator will be on and audible alarm will sound intermittently Now the output receptacles are supplied from the ba...

Страница 11: ...ion as well 4 Position 3 When PK1 is turned to this position the Load is supplied again by line voltage at during start up and after a short delay inverter starts running this can be seen by observing...

Страница 12: ...wer cords into outlets 4 2 15 20 30 kVA 4 2 1 Turn On Procedure 1 Turn On Main Switch PK1 on the front panel from position 0 to 3 step by step as in the instructions given in chapter 3 4 2 2 Turn on t...

Страница 13: ...onal sections LED indications and control and display As can be seen the upper section consists of leds which indicate the operation mode This panel shows the systems operation such as input and outpu...

Страница 14: ...LINE MODE UPS operating mode LINE FAILURE You have no AC input at the UPS input BATTERY TEST Performing battery test BAT AUTONOMY END Battery autonomy has finished BATTERY LOW UPS battery voltage is b...

Страница 15: ...g the batteries FAULT 7 Rectifier fault Please call service for checking the UPS FAULT 8 Line voltage out of tolerance 4 5 Automatic battery test system optional There are some conditions to make this...

Страница 16: ...oftware the UPS and the computer system communicate so that the computer system is warned of impending UPS shutdown Software RUPS RUPSII UPSILON SNMP devices is available for most operating systems an...

Страница 17: ...d to your network through SNMPVIEW Software supplied with the module or it is possible to monitor the UPS through an Internet Browser It is possible to shutdown the servers or users with Client mate S...

Страница 18: ...PS system from several different locations at the same time 5 5 UPS Port Sharer Multiple server shut down unit Using one of this units you can automatic shut down of 4 8 servers or PC where without LA...

Страница 19: ...18 SunLight Series UPS User Manual...

Страница 20: ...19 SunLight Series UPS User Manual Connection Diagram Of The RMP COM1...

Страница 21: ...persistent failure or problem properly turn off the unit first Then review the following check list Be prepared to answer the questions before calling the service 1 Did you follow the operation proced...

Страница 22: ...not apply if the product has been subjected to physical abuse improper installation unauthorized service or modification 2 The sole responsibility of corporation under this warranty shall be limited...

Отзывы: