V6812-T00 Series
HD 1MP IP Minidome Camera
User Manual
Страница 1: ...V6812 T00 Series HD 1MP IP Minidome Camera User Manual ...
Страница 2: ...ration is subject to the following two conditions This device will not cause harmful interference This device must accept any interference received including interference that may cause undesired operations The V6812 T00 Series HD 1MP IP minidome cameras have been tested and found to comply with the limits for a Class A digital device pursuant to the FCC rules With these rules and regulations bein...
Страница 3: ...ommended by manufacturer Position power source and related wires to assure to be kept away from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation Indicates that the un insulated components within the product may carry a voltage harmful to humans Indicates operations that sho...
Страница 4: ...1 Equipment Connection 15 3 2 Software Installation 15 Chapter IV Basic Function Operation 18 4 1 Browsing Videos 18 4 2 System 21 4 3 Network Settings 27 4 4 Camera Settings 34 4 5 Audio Video Settings 39 4 6 Alarm Settings 49 4 7 Record Management 50 4 8 Account Settings 54 4 9 System Log 56 Appendix I Magnetic Ring Filter Instruction 58 Appendix II Questions Solutions 59 Appendix III Cable Diam...
Страница 5: ...act structure makes it easy to install Also this camera provides 3 axis adjustment easy to adjust the monitoring angle V6812 T00 series IP minidome camera is suitable for financial institutions telecommunications governments schools airports factories hotels museums city streets and other high resolution surveillance applications 1 2 Product Features Infinova s V6812 T00 series camera has the foll...
Страница 6: ... Microsoft Windows 7 Microsoft Windows XP IE browser version Microsoft Internet Explorer 6 0 or above 1 4 Product Model This manual is for the following models V6812 T0020SP Megapixel IP minidome camera 3 axis Day night 1 3 inch CMOS sensor H 264 M JPEG 1 0Mpx PoE Surface mount 2 8 12mm vari focal lens V6812 T0020PP Megapixel IP minidome camera 3 axis Day night 1 3 inch CMOS sensor H 264 M JPEG 1 ...
Страница 7: ...IRE AGC ON Exposure Scene Mode Manual mode Shutter priority mode Shutter Auto Manual 1 25s 1 8000s White Balance Auto Manual Incandescent light Cool white fluorescent light Sun light Cloudy Natrium light Gain Control Auto Manual Noise Reduction 3D Video Compression H 264 High profile M JPEG Maximum Resolution 1280 720 H 264 M JPEG Optional Resolution Major stream 1280 720 1024 768 800 600 Minor st...
Страница 8: ...rnet port Applicable Protocols IPv4 IPv6 TCP UDP IGMP DHCP FTP SNMP V3 SMTP NTP RTP RTSP RTCP HTTP HTTPS TSL SSL 802 1X QoS PPPoE DNS ARP ICMP UPNP DDNS Profile S Alarm 1 alarm input 1 relay output Power Supply PoE IEEE 802 3af Class 2 Power Consumption 3W Operating Temperature 14 F 122 F 10 C 50 C Storage Temperature 4 F 140 F 20 C 60 C Operating Humidity 0 90 RH non condensing Unit Dimensions H ...
Страница 9: ...re to unplug the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 Under the default setting the lens has been adjusted till the object in a 1 5m distance becomes clear The lens can be readjusted as per the actual surveillance scenes 9 The camer...
Страница 10: ... bubble Loosen the 3 Torx T20 screws with an L Shaped Torx wrench T20 and take off the bubble Step 2 Install camera module Install the camera module to the ceiling with 3 tapping screws Drill screw holes and cable hole at the desired position as per Figure 2 1 Unit mm Figure 2 1 ...
Страница 11: ... 2 2 Note The camera supports storage with TF card See the figure below for TF card slot Figure 2 3 The size of TF card is up to 32GB Step 3 Adjust camera angle Adjust the panning angle according to your surveillance direction ...
Страница 12: ...ning 0 360 Rotating 0 360 Tilting 75 75 Screw A Figure 2 4 Step 4 Install dome bubble Install the bubble flange to camera module Align the screw holes of the two parts and fasten the 3 Torx T20 screws with the L Shaped Torx wrench T20 With all the procedures finished user should further confirm whether each part of the device is properly and firmly connected ...
Страница 13: ...9 Figure 2 5 Dimensions Unit mm Figure 2 6 ...
Страница 14: ... as per the label Figure 2 7 Step 2 Install adapter Pre loosen M4 screws to make the blocks away from snap joints place the adapter through the hole screw the M4 screws to let the blocks to fasten the ceiling Figure 2 8 Step 3 Install camera module Loosen the 3 Torx T20 screws with an L Shaped Torx wrench T20 and take off the bubble ...
Страница 15: ...n head screws Figure 2 9 Step 4 Adjust camera angle Adjust the panning angle according to your surveillance direction Loosen Screw A to adjust tilting angle then fasten the screw Adjust the rotating angle to ensure upright video Adjust the rods in the lens to focus clear Figure 2 10 ...
Страница 16: ...asten the 3 Torx T20 screws with the L Shaped Torx wrench T20 Step 6 Install recessed mounting housing Align the 3 grooves of the housing with the 3 bolts in the adapter and lock them together Figure 2 12 With all the procedures finished user should further confirm whether each part of the device is properly and firmly connected ...
Страница 17: ... 2 13 Step 2 Install camera module Loosen the 3 Torx T20 screws with an L Shaped Torx wrench T20 and take off the bubble Install the camera module to the adapter with 3 M4X6 pan head screws Figure 2 14 Step 3 Adjust camera angle Adjust the panning angle according to your surveillance direction Loosen Screw A to adjust tilting angle then fasten the screw Adjust the rotating angle to ensure upright ...
Страница 18: ...Install the bubble flange to camera module Align the screw holes of the two parts and fasten the 3 Torx T20 screws with the L Shaped Torx wrench T20 Figure 2 16 With all the procedures finished user should further confirm whether each part of the device is properly and firmly connected ...
Страница 19: ... 2 Software Installation The installation procedures of V6812 T00 series camera image software are listed as follows 1 Login First start IE browser and enter IP address Enter user name and password in the pop up login interface The default IP address is http 192 168 1 100 the default subnet mask is 255 255 255 0 and the default gateway IP address is 192 168 1 254 For normal access correctly set lo...
Страница 20: ...hod 2 The prompt message as below will come out in the page after a successful login Right click Add on Disabled and select Run Add on Figure 3 2 Then the prompt of security warning will pop up to remind the user to install InfiPlayerAX control Click Install Figure 3 3 After InfiPlayerAX control is installed you can view the live video If it pops up reboot prompt please cancel reboot Then close al...
Страница 21: ...ions as shown in the following figure 3 Click Internet icon then click Custom Level to pop up the following interface 4 Select Enable or Prompt in the options of Download unsigned ActiveX controls 5 Select Privacy in the Internet options and uncheck the checkbox of Block pop ups Refresh the webpage and set up the ActiveX control as per the prompts and then live view interface appears normally By n...
Страница 22: ...ult subnet mask is 255 255 255 0 and the default gateway IP address is 192 168 1 254 For normal access please correctly set local IP parameters before system login The login interface is displayed as shown in figure below in English operating system Figure 4 1 User Login Do login the system with the default super user for the first time to run the software The system default Super User is admin pa...
Страница 23: ...ype In the H 264 major or minor stream type users can do recording snapshootting and audio in out settings Over browsing videos users can also select a proper video scale Click the button to snapshoot and to enter the storage path Default C InfiPlayerAX Picture V6812 T00 series supports local recording Click the recording button to start recording when the button changes to click it to stop record...
Страница 24: ...motion detection and privacy mask functions are disabled Click the buttons to enable them and then the buttons will be shown as Note only when motion detection or privacy mask is enabled you can set the corresponding function in Audio Video Settings refer to Section 4 5 3 or 4 5 4 for details Note the login web page language should be set to the same as that of PC s operating system Click the opti...
Страница 25: ...tings Network Settings Camera Settings including Basic Set Effect Set White Balance Reset Audio Video Settings Alarm Settings Account Settings Add Delete User Change Password Log etc Note The following instructions are used for the super user 4 2 System Click the navigation bar System and it displays the following three option tabs System Time and Advanced as shown in Figure 4 3 ...
Страница 26: ...Figure 4 4 Time Settings Time Zone Settings Time Zone Select the desired time zone in the scroll box and then click Save to save it There are 33 time zones for your selection If Daylight Saving Time is applied in your region please enable the daylight saving time After settings completed please click the button Save NTP Settings Set the NTP server s IP address synchronization interval etc After co...
Страница 27: ...ftware Update Free software update is provided for V6812 T00 series camera and this update service can reduce system maintenance budget According to system update requirement submitted by user we will send update letter for confirming the version of the product and provide the latest software for download and help user to update the V6812 T00 series camera Follow the steps below to update software...
Страница 28: ...ick Yes button run the program to finish the update The response time is due to the program type You may wait a long time for some program Do not power off during the update process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will...
Страница 29: ...reset to the factory default settings There is time prompt in the web page during reset After reset it will skip to new web page If current IP unchanged you can access web page directly If IP address resets to 192 168 1 100 you can t access web page Then you have to set PC s IP address to 192 168 1 section such as 192 168 1 25 After that access web page to change camera s IP address and save PC s ...
Страница 30: ...ine Reboot Click Reboot button the dialog box This operation will take 60 seconds are you sure to continue pop up Click OK and the system will restart There is time prompt in the web page during reboot After reboot it will skip to new web page Note Available only for the super user ...
Страница 31: ...etwork FTP SMTP HTTPS 802 1X QOS IGMP SIP and MDA 4 3 1 Network Settings In the Network Settings interface as shown in the figure above users can enable or disable DHCP When it is disabled users can set Unit IP address Subnet mask Gateway and DNS server IP address manually Notes The system indicator quickly flickers for 5s after the network settings completed ...
Страница 32: ...eartbeat package will be sent to the server or client which greatly facilitates the server or client to know about the camera s network status 4 3 2 FTP Settings Figure 4 10 FTP Settings V6812 T00 series camera has the function of alarm associated with FTP upload alarm triggered image snapshot Configure server IP user name and password in the FTP settings and activate FTP handling way in alarm set...
Страница 33: ...copy to Authentication Enable or disable authentication function This function should be set according to authentication requirements of mail server User name Sender s name it can be set according user s needs Password Set sender s password Note there is no limit for Sender s name and password settings After setting click Set Save to take effect If user selects mail in Alarm Settings interface sys...
Страница 34: ...ts HTTPS protocol You can import the CA certificate in the interface 4 3 5 802 1X Settings Figure 4 13 802 1X Settings V6812 T00 series camera supports 802 1X protocol You have to enable 802 1X authentication when needed Then select an EAP method and enter the user name and password ...
Страница 35: ... Normal Service 2 Max Reliability 3 Max Throughput 4 Min Delay Recommended Normal Service 4 3 7 IGMP Settings Figure 4 15 IGMP Settings V6812 T00 series camera supports multicast function In the IGMP interface users can select the stream type and set the state multicast IP address and RTP port ...
Страница 36: ...the ID of SIP server Device ID the device ID used for registration with SIP server Alarm ID the ID registered for device alarm Register Interval the interval for re registration of device in seconds Heat Beat Interval the interval to send heatbeat information by the device in seconds After configuration completed click Save and the device sends a registration request to the server ...
Страница 37: ...mounting position as precise to two places of decimal 4 3 9 MDA Settings Figure 4 17 MDA Settings In MDA settings interface you can set the Sever which the motion detection alarm uploads to State disable or enable motion detection alarm upload When it s on you can set camera name user name password server IP and Port number After setting completed click Save button to take effect ...
Страница 38: ...interface shown as below Figure 4 18 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz Enable or disable backlight compensation or digital WDR Contrast Enhance 1 6 levels match with 6 kinds of Gamma curve separately If ...
Страница 39: ... aperture ICR control ICR switch time scene AGC shutter speed and manual AGC can also be set in this interface Exposure Set Manual Scene and Shutter priority In the Scene mode indoor or outdoor can be selected and AGC can be set maximum 64X if set to manual mode shutter speed can be set from 1 25s to 1 8000s and manual AGC can be ...
Страница 40: ...ol the day night switching in Day mode videos are in color mode in Night mode videos are in black white mode in IO input 1 mode ICR is controlled by external signals AE target set AE target level It can adjust video brightness via AE target setup 4 4 3 Effect Settings In the Effect Settings interface users can adjust the brightness sharpness hue contrast saturation and 3D denoise in two ways Gener...
Страница 41: ...37 Drag the sliding block to adjust the brightness sharpness hue contrast saturation and 3D denoise Figure 4 21 Effect Set Mode ...
Страница 42: ...SrMode Each mode matches with a group of parameters such as brightness sharpness hue contrast saturation and 3D denoise In the Mode call users can set effect mode call status and call period 4 4 4 White Balance Settings Figure 4 22 White Balance Settings The camera has rich white balance modes including Auto Manual Incandescent light Cool white fluorescent light Sun light Cloudy and Natrium light ...
Страница 43: ... the button Audio Video in the navigation bar to display the following interface Figure 4 23 Video Settings Click the related option tab to enter the setting interface 4 5 1 Video Settings Users can set the video parameters in the format of H 264 major or minor stream and MJPEG stream such as resolution frame rate and IP rate Resolution ...
Страница 44: ...ttings of H 264 major minor stream are linkage with that of MJPEG stream If H 264 major stream is set to 720P 30fps minor stream closed MJPEG is only able to set to 720P 4fps If H 264 major stream is set to 720P 25fps minor stream closed MJPEG frame is able to set to 10fps Do operate according to the prompt on the page GOV number GOV number means the ratio of I frame to P frame in compressed video...
Страница 45: ...mage is transmitted under a constant bandwidth Bit Rate Upper Limit You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate Upper Limit For major stream the bit rate upper limit can be 1000Kbps 10000Kbps for minor stream the bit rate upper limit can be 256Kbps 2000Kbps 4 5 2 OSD Figure 4 24 OSD M...
Страница 46: ...ny of whole numbers from 0 to 99 Font Size Set the font size to be displayed The bigger the value is the larger the font size is Default as 3 After all settings finished click Save button to display OSD on the video To cancel OSD set it to Off and then click the button Save See the figure for OSD Mode 2 Figure 4 25 OSD Mode 2 Only if Text 1 Text 2 and Date OSD are set to On you can set the text co...
Страница 47: ...el OSD set it to Off and then click the button Save 4 5 3 Privacy Mask V6812 T00 series camera supports 4 privacy masks If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do ...
Страница 48: ...r Click the button Draw with the mouse press the left mouse button and drag on the video till a blue frame displays on the screen Then click the button Save with the left mouse button and the blue frame changes into black which indicates a successful setting To cancel a privacy mask just cancel the box ticking ...
Страница 49: ...ion in Live View interface before motion detection setting see Section 4 1 Tick the box of Zone number to be set If the motion detection area has been set a blue frame will be displayed on the screen How to set the motion detection area How to set the motion detection area Tick the box of motion detection area number Click the button Draw with the mouse press the left mouse button and drag on the ...
Страница 50: ...elter Alarm Figure 4 28 V6812 T00 series camera supports shelter alarm function Users can easily set the shelter alarm areas with the mouse At first enable shelter alarm Click the button Draw with the mouse press the left mouse button and drag on the video till a blue frame displays on the screen Then click the button Save with the left mouse button and the blue frame changes into green which indi...
Страница 51: ...ng is visit 2 ch major stream 2 ch minor stream and 2 ch MJPEG video via 90 port and visit 3 ch major stream 3 ch minor stream and 3 ch MJPEG video via RTSP port 4 5 7 Storage Path You can set the photo saving path and recording saving path in the following interface Figure 4 30 Storage Path Default photo saving path C InfiPlayerAX Picture Default video saving path C InfiPlayerAX Video Photo and v...
Страница 52: ...48 To change the saving path click the button Browse and select the path from the popup dialog box 4 5 8 Audio Settings Figure 4 31 Audio Settings Sample Rate 8K Format G 711 U ...
Страница 53: ...s Alarm Configuration I O In 1 I O In 2 Settable 2 channel alarm inputs Each alarm input has 2 modes Grounded Circuit or Open Circuit Alarmout Contact used to set sending way of alarm Local Contact I O out is triggered by I O alarm in motion detection alarm shelter alarm SD card out network link down or IP address conflict Default ...
Страница 54: ...detection alarm shelter alarm SD card out network link down or IP address conflict which can be Alarm out 1 if Net Contact is selected Alarm output 1 on the web page is unavailable SD card Mail FTP or Audio After setting completed click Set button to take effect Alarm Schedule V6812 T00 series camera can set the effective alarm schedule Select the alarm period if Sunday is selected alarm will be e...
Страница 55: ...Recording mode Event triggered Always Close If Event Triggered is selected the event triggered can be Network disconnection or alarm If Network disconnection is selected recordings are automatically triggered during the period of network breaking if Alarm is selected also with SD card selected under alarm out contact in the alarm interface recording is automatically triggered when alarm occurs You...
Страница 56: ...4 7 2 Replay Figure 4 34 Replay Video Search set the start and end time and then click the search button All videos recorded during this period of time will display in the list Figure 4 35 Searching Videos ...
Страница 57: ...ht of video window the right window will disappear show as below Figure 4 36 Click the button the interface will return to the page as Figure 4 35 Download You can download the videos stored in the SD card to your PC Select the file from the video list also you can select multiple files simultaneously using the key Ctrl or Shift and then click the button Download to enter the downloading interface...
Страница 58: ...n to enter download content 4 8 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super user cannot change his own password A maximum of 8 accounts are supported Detailed instruction about how to add and delete user are addressed below Click the Account option tab in the Settings interface the following acc...
Страница 59: ...o special character is allowed The string length of user name is legal between 1 and 24 characters and that of password is between 5 and 20 characters 3 Click OK button If the setting is successful the new user name will appear in the account list Take new user user1 as an example Figure 4 40 2 Delete Users In the Account setting interface click button of the Operation item to delete user The foll...
Страница 60: ...t would be automatically updated 3 User Password Change Click button in the account list the dialog box of Edit User Information will pop up Figure 4 42 Input the old password enter the desired new password for twice and then click OK button the following picture will appear Figure 4 43 ...
Страница 61: ...d log information will appear on the right of the screen Figure 4 44 It can display 30 logs on a page The user can turn over the pages or skip to the desired page by clicking the below arrows Click Delete logs a prompt will come out Then click Yes to clear logs ...
Страница 62: ...ring filter and lead the power cable through Step 2 Wire the power cable on the magnetic ring filter 3 rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magneti...
Страница 63: ...upply Switcher insufficient Shorten the length of the power supply network cable or replace Power Supply Switcher of larger power The network camera does not perform initiation after power on If PoE power supply is used connection to other electric appliance make the ground level not in the correct level Disconnect other electrical appliance The plug in for viewing image is installed incorrectly R...
Страница 64: ...ameter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 6...
Страница 65: ...e Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to...
Страница 66: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V1 3 1405 ...