![Infineon XDPP1100 Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/infineon/xdpp1100/xdpp1100_technical-reference-manual_2055193129.webp)
User Manual
129 of 562
V 1.0
2021-08-25
XDPP1100 technical reference manual
Digital power controller
Digital pulse width modulator
Figure 56
t1 and t2 placement for TE, LE and DE modulation
ramp count = 0
ramp count = ramp_max
t1 = 0
t1 = 0
t1 = 0
t1 = 0
a) t1, t2 placement using trailing edge modulation
t2
t2
t2
Ramp Count
PWM
ramp count = 0
ramp count = ramp_max
t2 = ramp_max
b) t1, t2 placement using leading edge modulation
t1
t1
t1
Ramp Count
PWM
t2 = ramp_max
t2 = ramp_max
ramp count = 0
ramp count = ramp_max
c) t1, t2 placement using dual edge modulation
t1
Ramp Count
PWM
t2
t1
t2
t1
t2
t1