Foreign object detection tuning guide for wireless power transmitters
Applicable for WLC ICs
FOD functionality verification
4
FOD functionality verification
The following tests from the Qi compliance test suite can ensure an appropriate tuning of the FOD parameters
for BPP devices:
1.
Test#25 (a)
2.
Test#25 (b)
3.
Test#25 (c)
4.
Test#25 (d)
The following tests from the Qi compliance test suite can ensure an appropriate tuning of the FOD parameters
for EPP devices:
1.
MP.TX.FOD.OPERATE.FOD.REACT.TC1
2.
MP.TX.FOD.OPERATE.FOD.REACT.TC1a
3.
MP.TX.FOD.OPERATE.FO.CRIT.TC1
4.
MP.TX.FOD.OPERATE.FO.CRIT.TC1a
5.
MP.TX.FOD.BEFOREPOWER.FO.CRITIC.TC1
6.
MP.TX.FOD.BEFOREPOWER.FO.CRITIC.TC1a
Tests 1 and 2 validate the Threshold_max setting in EPP devices. The critical section tests (3 through 6) validate
the Q factor and threshold settings. Refer to
for details of the tools required for the Qi-recommended
validation test setup, test procedure and pass criteria.
Free-air FO can be tested by placing a US nickel or an Indian 2 coin on the interface at the center of the coil.
This should be indicated by the FO UI (user manual for FO indication).