XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-139
V2.1, 2008-08
SCU, V1.13
PVC1CONA1
PVC_1 Control for Step 1 Set A Register
ESFR (F016
H
/0B
H
)
Reset Value: 0000
H
PVC1CONA2
PVC_1 Control for Step 2 Set A Register
ESFR (F018
H
/0C
H
)
Reset Value: 0000
H
PVC1CONA3
PVC_1 Control for Step 3 Set A Register
ESFR (F01A
H
/0D
H
)
Reset Value: 0000
H
PVC1CONA4
PVC_1 Control for Step 4 Set A Register
ESFR (F01C
H
/0E
H
)
Reset Value: 0000
H
PVC1CONA5
PVC_1 Control for Step 5 Set A Register
ESFR (F01E
H
/0F
H
)
Reset Value: 0000
H
PVC1CONA6
PVC_1 Control for Step 6 Set A Register
ESFR (F020
H
/10
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
L2
AS
EN
L2
RST
EN
L2
INT
EN
L2
A
LEV
0
LEV2V
L1
AS
EN
L1
RST
EN
L1
INT
EN
L1
A
LEV
0
LEV1V
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type
Description
LEV1V
[2:0]
rw
Level Threshold 1 Voltage Configuration
This bit field defines the level of threshold 1 that is
compared with the DMP_1 core voltage..
The values for the different configurations are listed
in the data sheet.
L1ALEV
4
rw
Level Threshold 1 Action Level
0
B
The action configured by bits L1INTEN,
L1RSTEN, and L1ASEN are requested when
the voltage is below LEV1V. Otherwise no
action is requested.
1
B
The action configured by bits L1INTEN,
L1RSTEN, and L1ASEN are requested when
the voltage is equal or above LEV1V.