![Infineon Technologies TC1796 Скачать руководство пользователя страница 875](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437875.webp)
TC1796
System Units (Vol. 1 of 2)
LMB External Bus Unit
User’s Manual
13-97
V2.0, 2007-07
EBU, V2.0
13.10.7
Bus Access Parameter Register, BUSAPx
EBU_BUSAPx (x = 0-3)
EBU Bus Access Parameter Register
(100
H
+x*8
H
)
Reset Value: FFFF FFFF
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
ADDRC
1
CMDDELAY
WAITRDC
WAITWRC
BURSTC
rw
rw
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DATAC
RDRECOVC
WRRECOVC
DTARDWR
DTACS
rw
rw
rw
rw
rw
Field
Bits
Type Description
DTACS
[3:0]
rw
Recovery Cycles between Different Regions
This bit field determines the number of clock cycles of
the Recovery Phase between consecutive accesses
directed to different regions. The total number of this
type of Recovery Phase clock cycles is defined by
DTACS multiplied by the factor selected by
EBU_BUSCONx.CMULT (see also
).
0000
B
No Recovery Phase clock cycles available.
0001
B
1 clock cycle selected.
…
B
…
1110
B
14 clock cycles selected.
1111
B
15 clock cycles selected.