The Channel x Conversion Result Register RCHx contains the conversion result ADRES
of channel x.
RCHx (x = 0-3)
Channel x Conversion Result Register
(40
H
+x*4
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
ADRES
r
rwh
Field
Bits
Type Description
ADRES
[9:0]
rwh
AD Conversion Result
This bit field contains the conversion result of
channel x. ADRES can only be overwritten by
software if GCR.RESWEN = 1 (see also register
GCR description on
0
[31:10]
r
Reserved