![Infineon Technologies TC1796 Скачать руководство пользователя страница 1834](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371834.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-179
V2.0, 2007-07
GPTA, V2.0
Note: GTCXRk is write-protected when control bits CAC and OSM are set to 1 (“capture
after compare” in Single Shot Mode). Write protection is activated, when the value
of the selected GT timer matches and/or exceeds the capture/compare register
contents. Write protection is released after a software access to register GTCXRk.
OIA
14
rw
Output Immediate Action
0
B
No immediate action required.
1
B
Action defined by OCM must be performed
immediately.
Reading bit OIA always returns 0.
OUT
15
rh
Output State
0
B
GTCkOUT output line is 0.
1
B
GTCkOUT output line is 1.
0
9,
[31:16]
r
Reserved
Read as 0; should be written with 0.
GPTA0_GTCXRk (k = 00-31)
GPTA0 Global Timer Cell X Register k
(104
H
+k*8
H
)
Reset Value: 0000 0000
H
GPTA1_GTCXRk (k = 00-31)
GPTA1 Global Timer Cell X Register k
(104
H
+k*8
H
)
Reset Value: 0000 0000
H
31
24 23
0
0
X
r
rwh
Field
Bits
Type Description
X
[23:0]
rwh
Capture/Compare Register Contents of GTCk
0
[31:24] r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description