![Infineon Technologies TC1796 Скачать руководство пользователя страница 1675](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371675.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-20
V2.0, 2007-07
GPTA, V2.0
position. Dynamic information (speed, acceleration, deceleration) may be obtained by
analyzing the angular velocity signal periods with the associated DCM cell.
The maximum input frequency is
f
GPTA
/4 for a 2-sensor positioning system and
f
GPTA
/6
for a 3-sensor positioning system. To ensure that a transition of any input signal is
correctly recognized, its level should be held high or low for at least two
f
GPTA
cycles
before it changes (three
f
GPTA
cycles for a 3-sensor positioning system).
Figure 24-12 Block Diagram of Phase Discrimination Logic Unit
MCB05921
2
FPC0
Phase
Discrimation
Logic
PDL0
F0
B0
DCM0
2
2
2
FPC1
FPC2
DCM1
2
PDL0
PDL1
PDL2
PDL3
PDL Bus
TSE0
MUX0
ERR0
PDLCTR
Set
2
FPC3
Phase
Discrimation
Logic
PDL1
F1
B1
DCM2
2
2
2
FPC4
FPC5
DCM3
2
TSE1
MUX1
ERR1
Set
PDLCTR
Mux
Mux
Mux
Mux
≥
1
≥
1