MLI, V2.0
P8_IOCR0
Port 8 Input/Output Control Register 0(10
H
)
Reset Value: 2020 2020
H
31
28 27
24 23
20 19
16 15
12 11
8 7
4 3
0
PC3
0
PC2
0
PC1
0
PC0
0
rw
r
rw
r
rw
r
rw
r
Field
Bits
Type Description
PC0,
PC1,
PC2,
PC3
[7:4],
[15:12],
[23:20],
[31:28]
rw
Port Input/Output Control for Port 8 Pins 0-4
1)
Port input/output control for P8.0/TCLK1
Port input/output control for P8.1/TREADY1A
Port input/output control for P8.2/TVALID1A
Port input/output control for P8.3/TDATA1
1) Coding of bit field see
. Shaded bits and bit fields are “don’t care” for MLI I/O port control.
P8_IOCR4
Port 8 Input/Output Control Register 4(14
H
)
Reset Value: 2020 2020
H
31
28 27
24 23
20 19
16 15
12 11
8 7
4 3
0
PC7
0
PC6
0
PC5
0
PC4
0
rw
r
rw
r
rw
r
rw
r
Field
Bits
Type Description
PC4,
PC5,
PC6,
PC7
[7:4],
[15:12],
[23:20],
[31:28]
rw
Port Input/Output Control for Port 8 Pins 4-7
1)
Port input/output control for P8.4/RCLK1A
Port input/output control for P8.5/RREADY1A
Port input/output control for P8.6/RVALID1A
Port input/output control for P8.7/RDATA1A
1) Coding of bit field see