![Infineon Technologies TC1796 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437135.webp)
TC1796
System Units (Vol. 1 of 2)
CPU Subsystem
User’s Manual
2-38
V2.0, 2007-07
CPU, V2.0
The DMI Synchronous Trap Flag Register, DMI_STR, holds the flags that identify the
root cause of a Data-access Synchronous Bus Error (DSE). Reading DMI_STR in
supervisor mode returns the register contents and then clears its contents. Reading
DMI_STR in user mode returns the contents of the register but does not clear its
contents.
DMI_STR
DMI Synchronous Trap Flag Register
(F87FFC18
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
LBE
STF
0
LRE
STF
r
rh
r
rh
Field
Bits
Type Description
LRESTF
0
rh
Load Range Synchronous Error
0
B
No error
1
B
Load range synchronous error has occurred
LBESTF
2
rh
Bus Load Synchronous Error
0
B
No error
1
B
Bus load synchronous error has occurred
0
1,
[31:3]
r
Reserved
Returns 0 when read.