TC1796
System Units (Vol. 1 of 2)
Register Overview
User’s Manual
18-45
V2.0, 2007-07
Regs, V2.0
GPTA1_
DCMCOV1
GPTA1 Duty Cycle
Measurement Capture/
Compare Register 1
F000 209C
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMCTR2
GPTA1 Duty Cycle
Measurement Control
Register 2
F000 20A0
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMTIM2
GPTA1 Duty Cycle
Measurement Timer
Register 2
F000 20A4
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMCAV2
GPTA1 Duty Cycle
Measurement Capture
Register 2
F000 20A8
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMCOV2
GPTA1 Duty Cycle
Measurement Capture/
Compare Register 2
F000 20AC
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMCTR3
GPTA1 Duty Cycle
Measurement Control
Register 3
F000 20B0
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMTIM3
GPTA1 Duty Cycle
Measurement Timer
Register 3
F000 20B4
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMCAV3
GPTA1 Duty Cycle
Measurement Capture
Register 3
F000 20B8
H
U, SV U, SV 0000 0000
H
GPTA1_
DCMCOV3
GPTA1 Duty Cycle
Measurement Capture/
Compare Register 3
F000 20BC
H
U, SV U, SV 0000 0000
H
GPTA1_
PLLCTR
GPTA1 Phase Locked
Loop Control Register
F000 20C0
H
U, SV U, SV 0000 0000
H
GPTA1_
PLLMTI
GPTA1 Phase Locked
Loop Microtick Register
F000 20C4
H
U, SV U, SV 0000 0000
H
GPTA1_
PLLCNT
GPTA1 Phase Locked
Loop Counter Register
F000 20C8
H
U, SV U, SV 0000 0000
H
GPTA1_
PLLSTP
GPTA1 Phase Locked
Loop Step Register
F000 20CC
H
U, SV U, SV 0000 0000
H
Table 18-21 Address Map of GPTA1
(cont’d)
Short Name Description
Address
Access Mode Reset Value
Read
Write