4.3.4.1
LMB Bus Control Unit Control Registers
The identification register allows the programmer version-tracking of the module. The
table below shows the identification register which is implemented in the LBCU module.
LBCU_ID
Module Identification Register
(008
H
)
Reset Value: 000F C0XX
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MOD_NUMBER
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
MOD_TYPE
MOD_REV
r
r
Field
Bits
Type Description
MOD_REV
[7:0]
r
Module Revision Number
This bit field defines the module revision number.
The value of a module revision starts with 01
H
(first
revision).
MOD_TYPE
[15:8]
r
Module Type
The bit field is set to C0
H
which defines the module
as a 32-bit module.
MOD_NUMBER
[31:16]
r
Module Number Value
This bit field defines a module identification number.
The value for the LBCU module is 000F
H
.
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...