![Infineon Technologies TC1784 Скачать руководство пользователя страница 331](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_2055446331.webp)
TC1784
System Control Unit (SCU)
User´s Manual
3-148
V1.1, 2011-05
32-bit SCU, V1.18
3.9.1
Emergency Stop Register
The Emergency Stop Register EMSR contains control and status bits/flags of the
emergency stop input logic.
EMSR
Emergency Stop Register
(100
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
EMSFM
0
EMS
F
r
w
r
rh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
EN
ON
MO
DE
POL
r
rw
rw
rw
Field
Bits
Type Description
POL
0
rw
Input Polarity
This bit determines the polarity of the input line.
0
B
Input is high active
1
B
Input is low active
MODE
1
rw
Mode Selection
This bit determines the operating mode of the
emergency stop signal.
0
B
Synchronous Mode selected; emergency stop
is derived from the state of flag EMSF
1
B
Asynchronous Mode selected; emergency stop
is directly derived from the state of the input
signal
ENON
2
rw
Enable ON
This bit enables the setting of flag EMSF by an
inactive-to-active level transition of input signal.
0
B
Setting of EMSF is disabled
1
B
Setting of EMSF is enabled
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...