Heterodyne Feature

Whisper features heterodyne capability, which converts the ultrasonic frequencies 
to sounds that can be heard by the human ear. This allows you to easily isolate 
the ultrasonic source.
Plug the included headphones into the jack on the right side of Whisper to enable 
heterodyne capability. Dragging your finger upward/downward on the sensitivity 
touch pad will increase/decrease the volume of the headphones. 

NOTE:

Sensitivity defaults to a lower level when headphones are plugged in to 
protect against hearing damage. Use the touch pad to increase sensitivity 
if needed. 

Laser Pointer Feature

Whisper (if equipped) features an integrated laser pointer. This feature is 
designed to aid in pinpointing leak sites. To enable/disable the laser pointer 
feature, briefly press the power button. The laser pointer will automatically disable 
if Whisper is turned Off.

NOTE:

Laser pointer not available in Japan.

WARNING

Do not aim the laser pointer at any person or animal.

High Noise Environments

In noisy environments, it may be necessary to “tune out” unwanted signals from 
other areas in close proximity to where you are scanning for leaks. Begin by 
pushing the rubber extension probe over the nose piece. When the extension is 
attached, Whisper’s sensing angle is reduced, increasing the directional capability 
and reducing the effects of the adjacent noise sources. This allows Whisper's 
detection capabilities to become more directional. If you suspect the reading 
originates from a source other than what you are scanning, point the probe toward 
the suspected source (maybe a compressor, V-belt, discharging steam line, etc.) 
and slowly decrease sensitivity until the alarm stops. Turn the probe back in the 
direction of the suspected leak and continue to scan. This step may have to be 
repeated as you move around to other locations in search of leaks. If the probe is 
close to internal moving parts of equipment, and the alarm sounds, push the 
rubber probe against the equipment housing. If the alarm still sounds, internal 
friction of moving parts, and not a leak source, may be causing the alarm.

Содержание WHISPER

Страница 1: ...O P E R A T I N G M A N U A L Whisper Ultrasonic Leak Detector ...

Страница 2: ...ety requirements for electrical equipment for measurement control and laboratory use General requirements IEC 60825 1 2014 Safety of Laser Products Part 1 Equipment Classification and requirements Emissions CISPR 11 EN 55011 2009 Emission standard for industrial scientific A1 2010 and medical ISM radio RF equipment Class B Immunity EN 61326 1 2013 Edition 2 0 EMC Measurement Control Laboratory Equ...

Страница 3: ...ardous and damaging to eyes Never aim a laser pointer anywhere at or near any person or animal Laser pointers are designed to point at inanimate objects only In some states and provinces it is illegal to aim a laser pointer at a law enforcement officer or any other person The purchaser user is responsible for ensuring that his or her use of the laser pointer conforms to any local laws Do not point...

Страница 4: ...rough a 0 004 in 0 01 cm diameter orifice at 5 0 psig from a 12 in 30 5 cm distance Usage Indoor or Outdoor Operating Temperature Range 32 F to 122 F 0 C to 50 C may be operated for a limited time in lower temperature environments Storage Temperature Range 14 F to 140 F 10 C to 60 C Humidity 85 RH NC Max Altitude 6500 ft 2000 m Power Supply 2 D cell alkaline batteries Battery Life with laser off A...

Страница 5: ...ating sources of ultrasonic disturbances created by gases liquids or solids Whisper has different ways of indicating these disturbances When used without headphones Whisper s indicators will illuminate and the unit will beep in response to sources of ultrasonic noise When headphones are plugged in Whisper s heterodyne feature is enabled bringing ultrasonic frequencies to a range audible to the hum...

Страница 6: ... noise Drag your finger downward on the sensitivity touch pad to reduce sensitivity in response to an increase in environmental noise Many variables can affect the amount of ultrasound generated by the leakage of gas through an orifice Such factors include the pressure vacuum relative to the surrounding environment how smooth the edges of the orifice are the diameter of the orifice Whisper s dista...

Страница 7: ... a slow X a vertical and horizontal type sweeping motion while keeping the nose piece or rubber extension probe pointed in the general direction of the suspected leak 4 If you are using Whisper without headphones it will beep when an ultrasonic disturbance is detected If you are using headphones Whisper will make a variety of different noises due to its heterodyne feature See Heterodyne Feature fo...

Страница 8: ...pointer at any person or animal High Noise Environments In noisy environments it may be necessary to tune out unwanted signals from other areas in close proximity to where you are scanning for leaks Begin by pushing the rubber extension probe over the nose piece When the extension is attached Whisper s sensing angle is reduced increasing the directional capability and reducing the effects of the a...

Страница 9: ... other moving parts Always use extreme caution when using the contact probe around machinery Whisper Transmitter Accessory if equipped Whisper Transmitter is an accessory which can be used with the Whisper Ultrasonic Leak Detector to locate leaks in walk in coolers freezers wall and ceiling joints around doors windows body seals rubber moldings ducts etc Whisper Transmitter produces the frequency ...

Страница 10: ...as power cells In addition INFICON does not warrant any instrument that has been subjected to misuse negligence or accident or has been repaired or altered by anyone other than INFICON INFICON s liability is limited to instruments returned to INFICON transportation prepaid not later than thirty 30 days after the warranty period expires and which INFICON judges to have malfunctioned because of defe...

Страница 11: ......

Страница 12: ...TWO TECHNOLOGY PLACE EAST SYRACUSE NY 13057 9714 USA Phone 1 800 344 3304 Fax 315 437 3803 E Mail service tools inficon com www inficonservicetools com 2017 INFICON 074 504 P1D ...

Отзывы: