background image

Type 0/1

24-230V AC

L
N

CIB+

CIB -

thermosensor

1. 

2. 

3. 

4073-02-001 Rev

.0

H

eating

1. Set contents

- PS-30/24 

power supply

- BPS2-01M 

bus/supply voltage separator

- CU2-01M 

central unit

- SA2-02B 

switching actuator

- Alpha AA 230V NO 

thermo valve

- IART2-01 

analog thermo-controller

2. First start of the set in box

Set is already „preprogrammed“ by the manufacturer and ready for using.
1. Check whether all conductors are connected to terminals (no one is loose or fell out).
2. Connect the mains plug into the 

AC 230 V

 socket.

3. The 

CU2-01M

 starts the starting sequence. After the sequence is completed, the 

CU2-01M

 switches to the 

RUN

 operation mode whereas this mode is 

signaled on the segmented display as 

G

4. Set started this way is ready for use according to functions already pre-programmed in  

CU2-01M

IART2-01

 analog thermo controller is programmed as follows:

Thermo sensor TC / TZ

Thermo-valve

1. Rotary element is designated for correcting  requested temperature -3°C/+3°C

2. Button 0/1 is designated for switching the heating circuit off -  green LED signalizes that the heating circuit is switched on;  
  when orange, the heating circuit is active (heats up).

3. Button hand/clock is designed for switching the heating modes -  first press switches to presentation (signalized by green LED),
  the second press switches to the forced comfort (signalized by  red LED), and the third press switches back into controlled time 
  schedule program.

A well-trained technician should always install the set. This simplified use instructions describe the set basic mounting; mounting details for single sections of the set are given in related manuals. 

The complete instructions on system parametrization are available on the CD enclosed.

USE INSTRUCTIONS

4. Set installation in designated location

1. Install the set in designated place.
2. Connect 

AC 230V

 mains supply voltage cable to 

PS-30-24

 power supply terminals 

 

N

 and 

L

.

3. Then continue in terms of point 2 - First start of the set in box.

3. Prior installation in designated location

1. Make sure all installation bus conductors are correctly connected into the 

CIB+

 and 

 

CIB-

 terminals.

2. Make sure that BPS2-01M bus/supply voltage separator is correctly connected into 
  the 

PS-30-24

 power supply.

5. Inels designer & manager (IDM) programming environment installation

IDM is used for activation and parametrization of the system, eventually for creating the basic visualization of  
INELS® intelligent electro-installation application.

1. Start 

IDM.exe file

, which is  located on attached CD.

2. After starting, window 

Installation guide language selection

 appears. 

3. Select  language and confirm your selection with 

OK

 button; then appears window IDM installation guide 

4. Follow the instructions of  

IDM product guide

.

5. After the IDM installation is done, 

history.txt

  file opens, that contains new IDM features description, 

  or description of corrected errors; at the same time introductory login window appears.

Отзывы: