16 Description of alarms
AL2
Primary inverter module overheat
AL3
Secondary inverter module overheat
AL4
Overvoltage, undervoltage or missing phase
AL5
Cooling unit error
AL6
Welding cables short-circuiting
AL7
Torch pushbutton pressed in the course of
generator switch-on
AL11
Indication of cooling unit voluntarily disabled
AL12
Indication of cooling unit voluntarily enbled is
not present
AL13
Logic board memory fault
AL24
System clock fault
AL25
Motherboard battery flat
17 Troubleshooting
A list of the possible failures of a SKYLINE HFP
generator is reported here below with the indication of
the possible causes.
A) The power source does not weld correctly. Check
that:
•
the type of welding is correct
B) If when starting the machine the display ‘D1’ is on but
the machine does not weld, check that:
•
check torch cable, power sockets and work return
lead for integrity
C) If the machine stops for overheating, when welding,
over 4 minutes, check that:
•
the air flow for the cooling of the components is not
hindered by dust or foreign objects placed in the
vicinity of the air vents
•
the fan is working properly
D) The machine works in MMA mode but not in TIG,
check that:
•
the electric contact of the torch trigger is properly
closed
E) Irregular welding:
•
make sure there is no draft while welding
•
make sure the gas flows regularly by checking gas
regulator, solenoid valve and connecting hoses