In the processes with synergy, selector switch ‘E1’
permits setting the arc height correction and the output
inductance. For changing these values:
•
Press selector switch ‘E1’ in sequence for lighting
the LED related to the parameter to be changed, and
rotate ‘E1’ itself for changing the value.
The voltage parameter ‘V’ can be setting only in no
synergic MIG/MAG (see operation SET ->
SYN
).
Via selector switch ‘E2’ it is possible to set the welding
current, the wire speed and the piece thickness. For
modifying these values:
•
Press selector switch ‘E2’ in sequence for lighting
the LED related to the parameter to be changed, and
rotate ‘E2’ itself for changing the value.
By keeping selector switch ‘E1’ pressed for more than
two seconds, you will go into the SET mode, where you
can set the following advanced parameters:
•
ER70S CO
2
CO2
:
sets the type of gas used in
welding SG2/3 wire (AWS ER70S). The gas types
supported are: Ar-18%CO
2
(M21) and Ar-8%CO
2
(M20).
•
Softstart
SOF
:
when the torch trigger is pressed the
wire is fed slowly, reaching the set speed only when
the welding arc strikes. It is automatically adjusted
(
SYN
on the display) or adjustable from 1 to 100% of
the speed set for the wire.
•
Burnback
BUR
:
it adjusts power delay with the aim
of optimising the end of the welding process (that is,
the length of the wire with respect to the end of the
torch). It is automatically adjusted (
SYN
on the
display) or adjustable from 1 to 100%.
•
Pregas
PRE
:
pre-gas time (seconds)
•
Postgas
POS
:
post-gas time (seconds)
•
Start cur
INI
:
initial current value / first level (for
3-level or 2-step + 3-level mode only)
•
Crater cur
CRA
:
final current value / third level (for
3-level or 2-step + 3-level mode only)
•
Start time
TIN
:
initial current time / first level (for
2-step + 3-level mode only)
•
Crater time
TCR
:
final current time / third level (for
2-step + 3-level mode only)
•
Synergy
SYN
:
to turn the synergy mode ON (1) or
OFF (0). In the manual mode it lets the user set all
the parameters exactly as they would be for
traditional MIG/MAG generators (adjustment of wire
tension, inductance and speed). This selection is not
available in MIG P or MIG DP because the
parameters need to be synergically controlled for a
correct pulsed arc welding.
Concluding notes
By means of the connector ‘C1’ on the front panel, the
machine may be controlled using optional remote
controls. The selection of the remote control is
automatic when the connector is inserted and remains
in this way until it is physically disconnected.
Storing programs and general settings
It is possible to store tailored welding recipes by using
the ‘E2’ selector switch. In total, 100 programmes can
be stored.
After set all the desired parameters, access the storage
menu by pressing the selector ‘E2’ for two seconds.
Save a program:
•
Rotate knob ‘E1’ and select
STO
(Store).
•
Rotate knob ‘E2’ for choosing the desired memory
location, shown on display ‘D2’.
•
If such chosen memory number is blinking, it means
it is free. On the contrary, if it is steady lit, it means
that it is already occupied: by confirming the
operation, the existing programme will be
overwritten.
•
Press ‘E2’ for two seconds to confirm or ‘E1’ to
cancel. The LED lights up blue ‘
3
’ for 2 seconds
indicates the save operation is complete.