Overview
The DM9032/DM9032-SA
SmartDome™
are part of Indyme
’s
Smart Sense
Solution Suite. Indyme smart devices use custom algorithms and
intelligent sensors to detect activity within the coverage area. The
SmartDome™
uses a Passive Infrared sensor to detect when someone is
dwelling in a coverage area beyond a defined threshold. Once detected, a
SmartD
ome™
can be programmed to activate both local and/or remote
alerts through the Indyme infrastructure. As a member of the Indyme
Global Solutions Family, the DM9032/DM9032-SA can also communicate
with other GSF devices. GSF and Smart devices operate in the 800-900MHz
frequency spectrum. They are not compatible with legacy devices.
SmartDome™
Programming
Indyme Smart devices are programmed using the cloud based Smartportal
website and the local Indyme infrastructure. (DM9032-SA is
preprogrammed in the factory.) Ensure the Indyme control unit and access
point(s) are installed and operational, with full access to Smartportal
before proceeding. Incomplete infrastructure will prevent programming of any Smart devices.
The DM9032-SA is preprogrammed to function directly out of the box. No additional programming is necessary.
The DM9032 device leaves the factory at default settings, these settings will NOT function in a customer environment.
All devices must be properly programmed using the Smartportal website. Smart devices use three primary
programming parameters; Location, Activity Profile and Alert Profile. These parameters will be provided with your
Work Order. Identify the locations and profiles before you begin programming.
•
Location
–
department in the store where the device will be
installed.
•
Activity Profile
–
setting used to indicate timing algorithms for
activation.
(default activity profile is “Cosmetic”)
•
Alert Profile
–
settings used to activate the local device alert tone
and LED.
(default alert profile is “On”)
Using your internet enabled device; cellphone, tablet or laptop, and the
credentials provided on your Work Order, login to the website,
https://smartportal.indyme.com
.
Follow the on-screen instructions to configure each DM9032, one at a time.
It is NOT advisable to have multiple users logged into the same Work Order.
Failure to follow these instructions will result in a failed installation of some or all devices.
NOTE: The DM9032 devices should be programmed while in the designated location OR after they are physically
mounted.