System
description
[email protected] | www.romanoff.com
2019-10-16
4
–6
4.5.2
MC16 modify program screen
Figure 6:
program
parameter
middle section with
program parame-
ter
Outer area with
choice
Display in the middle area:
0018
InduTest
‚0‘ to ‚19‘
Selected program to modify.
0010 °C
Temperature
‚10‘ to ‚1300‘
Set temperature inside the crucible.
0100 %
Heating power
‚10‘ to ‚100‘
You can reduce heating power here.
0000
Washing before
heating
‚0‘ to ‚5‘
Washing cycles before heating (starts
with vacuum, then backfill to 0.0 bar
with protective gas). Number displays
the cycles that will be done. It is rec-
ommended for palladium alloys (very
reactive).
0000
Washing while
heating
‚0‘ to ‚5‘
Washing cycles during the machine
heats.
Manual
Melting pressure
start
‚Automatic‘
Start of the melting pressure.
Pressure starts after the washing cy-
cles.
‚Manual‘
To start melting pressure, you need to
press the start button again.
–1.00 bar
Melting pressure
‚-1.00‘ to ‚0.00‘
bar
Melting pressure set value in chamber
during heating.
2.00 bar
Casting pres-
sure
‚-1.00‘ to ‚2.00‘
bar
Casting pressure set value.
Label
[InduTest 1]
Here you can change the name of the
program.
Display on the side:
Λ
Moves the input area (highlighted area) one level above.
V
Moves the input area one level below.
+
Increases the value within specified limits.
-
Decreases the value.
Main page
Display returns to main menu.
0018
Program InduTest 1
Λ
+
0010 °C
Temperature
0100 %
Heating power
0000
Washing before heat
0000
Washing while heat
V
Manual
Melt. press. start
–
–1.0 bar
Melting pressure
2.00 bar
Casting pressure
Label
[InduTest 1 ]
Main
Page
Page