86
6.12 Manifold Instructions
Up to five docking stations can be connected to one gas cylinder using the
Demand Flow Regulator, the Five Port Regulator Manifold Clamp, and the
DSSAC web application.
Through the DSSAC web application, the primary docking station settings
are used by all of the docking stations in the manifold.
DSSAC is used to control how the manifolded docking stations are affected
by the conditions of the primary docking station. Table 6-6 shows some
examples of these conditions, actions and results.
Table 6-6. Manifold correlations with DSSAC
Condition
Action
Result
Primary docking station
DSSAC Settings
Manifolded docking stations
The gas cylinder is replaced with the
same type of gas and cylinder.
No action required
The replaced cylinder is available for
use
The gas cylinder is replaced with a
different type of gas and cylinder.
Update gas and cylinder type
settings
The Different gas cylinder is available
for use
Disconnected
Update to “Disabled”
Disabled
Removed from service
Remove from DSSAC system
The manifold gas cylinder and primary
docking station are not available.
Note:
Manifolded docking stations can be connected to one or more primary docking stations.
The Manifold Kit
The Demand Flow Regulator is required for use with the Calibration Manifold Kit. Each kit
item, listed and shown below, should be accounted for during the unpacking process. If any item
is missing or appears to have been damaged, contact Industrial Scientific or a local distributor of
Industrial Scientific products.
Hardware overview
Item Identification
Thumb nuts
Five Port Gas Manifold
3/16″ polyurethane
tubing; one foot
section
1/8″ polyurethane
tubing; 8′ sections (x5)
Vinyl end cap
Luer caps
1/8″ female Luer
fittings (x5) *
1/8″ male Luer fittings
(x5)
5/32″ female Luer
fittings (x5) *
Содержание DSX-L
Страница 1: ...Start up Guide DSX L Local Server Mode Edition 9 January 24 2020 Part Number 17156008 ...
Страница 4: ...iv ...
Страница 8: ......
Страница 14: ......
Страница 21: ...17 3 For Installation Type choose Role based or feature based installation and click Next ...
Страница 24: ...20 ...
Страница 44: ...40 Step Instruction Figure 3 14 Entering the System Administrator Password 3 Start installation ...
Страница 64: ...60 13 Verify SQL has been added to the Exceptions list and click OK ...
Страница 83: ...79 Figure 4 11 Adding Gas from Industrial Scientific ...