3. Programming Module AS
3. Programming
Module AS
The programming module AS plugged into the controller serves to match
the controller to the main spindle motor and to create the operating
characteristic for the main spindle drive.
INDRAMAT supplies the appropriate programming module AS (stand-
ard version according to selection data) for each main spindle drive in the
product range.
INDRAMAT main spindle drives are microprocessor-controlled.
Due to its associated programming module AS, the main spindle drive is
immediately ready for start-up without any further matching operation
being required. The only pre-requisites are that the drive must have been
properly connected up (see section 2.4) and properly commissioned (see
section 9).
INDRAMAT main spindle drives can be matched by means of param-
eters to the specific machine configuration and the functional require-
ments of the application.
The programming module AS carries the operating software and the
parameters. Should a unit need to be replaced, the new controller does
not require to be matched, since it is immediately compatible with the
motor and the machine once the existing and already matched program-
ming module is plugged in.
Matched programming modules can be very easily duplicated for use on
other identical machines. This is done using the parameter duplicating
adapter or by transfer via a serial interface and a facility with a memory
(PC or similar).
The operating software comprises two groups of parameters:
– those specific to the drive, and
– those specific to the application
Drive parameters govern the operating characteristics of the drive. To
create the operating characteristics of the drives, INDRAMAT calculates
and determines the relevant parameter values.
Application parameters are used to activate the functions of the main
spindle drive or to modify them to suit the application, and thus to match
the drive to the machine.
The procedure for entering and editing parameter values is identical for
all INDRAMAT main spindle controllers. This is done using the keypad
on the control panel of the controller.
For more details, see the section "Operating the controllers" of the
documentation "A.C. main spindle drives with controlled asynchronous
motor or frameless spindle motor; Applications Manual" (No. 209-0041-
4109).
Rapid start-up of the drive
Benefit in the event
of unit replacement
Duplication
Parameters
Entering and editing
of parameter values