background image

_________________________________________________________________________________

 

FB

 

TS

 

ME7

 

01

                    

ICG®

 

Standard

 

Operating

 

Procedure

 

|

 

released

 

by

 

ICG®

 

Service

 

Department

                                                                   

1

 

 

 

IC7

 

Indoor

 

Cycle

 

 

MECHANIC

 

TROUBLESHOOTING

 

 

 

 

Содержание TOMAHAWK IC7

Страница 1: ...______________________________________________________________________________ FB TS ME7 01 ICG Standard Operating Procedure released by ICG Service Department 1 IC7 Indoor Cycle MECHANIC TROUBLESHOOT...

Страница 2: ...Horizontal slider remains in position while lever is closed and freely moving while lever opened NO Repeat adjustment process HANDLEBAR SEAT POST HORIZONTAL SLIDER MOVES WHILE CLOSED Problem solved Y...

Страница 3: ...couple and check freely sliding of the HB stem and twist of HB stem Twisting reduced NO YES Repeat adjustment process HANDLEBAR STEM WOBBLES TWIST Problem solved _____________________________________...

Страница 4: ...appears Check pedal torque value 45Nm YES Noise still appears Check crank mounting boltS torque value 60 Nm YES Replace generator Art No 150 01 00017 01 generator Replace BB bearings Art No 900 06 00...

Страница 5: ...e right shroud and check belt tension and adjust if necessary Slack still occur YES Problem solved NO Replace primary belt Art No 150 03 00045 01 ______________________________________________________...

Страница 6: ...hould provide a slight play Turn ferrale counterclockwise Open vertical adjustment to test seat post easily extending and compressing Extending and compressing easily NO YES Check bowden cable fitment...

Страница 7: ...ly extending and compressing Extending and compressing easily NO Close lever and apply load to Seat post to check seat post still sinks YES Perform loadtest extend saddle mark tube apply load on seat...