Indol 200A++ Скачать руководство пользователя страница 1

Operation & Installation Manual

Operation & Installation Manual

Air source hot water heat pump

Air source hot water heat pump

COMPACT

COMPACT

INDOL

INDOL

Содержание 200A++

Страница 1: ...Operation Installation Manual Operation Installation Manual Air source hot water heat pump Air source hot water heat pump COMPACT COMPACT INDOL INDOL...

Страница 2: ...rding to the manual Once finish the installation and connection please make everything ok before power on the unit The manufacture of this product will not be held responsible if someone is injured or...

Страница 3: ...Map 4 2 Choose the Suitable Unit 4 3 Deposited and Transportation 4 4 Installation Position 4 5 Water Loop Connection 4 6 Wire Connection 4 7 Trial Running 5 Usage 5 1 Icons Introduction 5 2 Operation...

Страница 4: ...per installation which can lead to water leakage electrical shock or fire Professional installer is required Earthing is required Please make sure that the unit and power connection have good earthing...

Страница 5: ...trical shock or fire may be occur When the heat pump need to be repaired please entrust dealer or qualified person to carry it out Improper movement or repair on the unit will lead to water leakage el...

Страница 6: ...s a timer for start and stop and an adjustment dial for easy setting of the water temperature depending upon the location of the air exchanger heat may be taken from the outside environment from a sun...

Страница 7: ...oderate temperature liquid Then the pressure of the liqiud refrigerant drops as it passes throttling device Finally refrigerant absorbs heat from the surrounding air and evaporates into vapor with low...

Страница 8: ...and right sides and 1 at the back 7 in total 5 2 Specs 2 4 Dimensions Unit mm Dimention Model Indol Compact 200A C B Condensation water outlet A Overheating protector Eletricity heater Drainage E F D...

Страница 9: ...e of the operating water pressures 0 15 0 7MPa Model Heating capacity Water tank capacity Power input Running current Power supply Compressor Number Compressor Rated outlet water Temp Air volume Air p...

Страница 10: ...the unit correctly please run the unit at environment temperature 0 40 The unit includes sophisticated electronic devices prohibited to use water from lake untreated river water and groundwater Power...

Страница 11: ...stallation 4 1 Installation Sketch Map Air inlet 160mm pipe Drainage Cold water inlet Manual valve Air outlet Condensation water outlet Hot water outlet NOTE A safety valve MUST be installed on water...

Страница 12: ...transported by a fork lift the unit must remain mounted on the pallet The lifting rate should be kept to a minimum Due to its top heaviness the unit must be secured against tipping over To prevent an...

Страница 13: ...d heat exchanger of the hot water heat pump enables direct connection to a second heat generator e g a solar heating system or a boiler 2 Dehumidification in the recirculating air mode see picture bel...

Страница 14: ...n 1 Choose the right path to move the unit 2 Try to move the unit as original case 3 If the unit installed in the building of the metal part it must work for electrical insulation and comply with the...

Страница 15: ...installation has to be executed in compliance with DIN 1988 in case of excessive water pipe pressure a pressure relief valve is to be provided The water pipes may be of the rigid of flexible type to...

Страница 16: ...2 3 4 5 6 ON OFF Mode Electric Heater Up Down Turn on off the unit Switch unit running modes or save setting parameters Set the clock or the timer Turn on off the electric heater or switch fan modes M...

Страница 17: ...play area displays the minute Second Shows that the main display area displays the second Centigrade Shows that the temperature in Main display area or Auxiliary display area is in Fahrenheit Shows th...

Страница 18: ...gent Running interface 2 1 Turn ON OFF the unit Press and hold for 0 5s in the standby interface of the wire controller to turn on the unit and at this time the main display area shows the water outle...

Страница 19: ...ure After making the changes to the parameter press to confirm or to cancel the changes then return to the previous interface If no operations are performed on the keypad for 5s the controller exits t...

Страница 20: ...do as follows to set the time when in heating mode When press once the time parameter will flash When press again the hour parameter will flash then press or to change it After making the changes to t...

Страница 21: ...timer1 setting you can set the turn on time of timer2 After finishing the OFF and 2 will flash and then you can set the turn off time of timer2 Press again to save and back to the interface If you do...

Страница 22: ...nto the next setting without confirm the previous one ON 2 Press and hold for 2s to enter into the next setting without confirm the previous one Press and hold for 2s to enter into the next setting wi...

Страница 23: ...20 00 Outlet water temperature Current time Press and hold for 2s ON 1 OFF 1 Press to confirm Successful setting Press to cancel the setting and exit Without saving Confirm the time after setting Con...

Страница 24: ...lashing at this time Then set the date in the same way as 2 4 Example Set the start up date on September 28 Note Turn off the unit before going out Vacation mode Outlet water temperature The current d...

Страница 25: ...Usage 22 2 5 3 If you want to cancel the timer setting follow this below press to cancel all the operation Outlet water temperature Timer state Pressing lasting for 2S The ON and 1 icons are flashing...

Страница 26: ...op running when the unit target temperature is reached Definition of the fan icon 1 Running shows that the fan is running at high speed 2 Running shows that the fan is running at low speed 3 Fan icon...

Страница 27: ...5 Usage 24 2 8 Keyboard locking Press and hold for 5s once to lock the keyboard Press and hold for 5s again to unlock the keyboard Press and hold for 5s Lock icon...

Страница 28: ...ilure part if there is any and recharge the refrigerant if it is needed If the heat pump is not used for a long time please drain out all the water in the unit and seal the unit to keep it good Please...

Страница 29: ...tank temp sensor is open or short circuit The ambient temp sensor is open or short circuit The pipe temp sensor is open or short circuit The evaporator temp Sensor is open or short circuit The exhaus...

Страница 30: ......

Страница 31: ...Code 20201120 0001 Code 20201120 0001...

Страница 32: ...0 C6 88 9 1 3 41 70 H D 5 A 27 B8 6 3...

Отзывы: