Requirement
Specification and quantity of hydraulic fluid or lubricating oil and
grease in accordance with information in the technical data.
The spare parts and utilities as well as operating fluids required for repair or
maintenance should already be available in sufficient quantities.
This is especially true for necessary special tools, without which the maintenance or
repair would not be possible.
Procedure
1.
Example: Illustration of HSK clamping set
1
Brass ring
2
Grooved ring
3
O-ring
4
O-ring
Check grooved ring (2) in clamping taper.
2. Replace grooved ring, if necessary.
3. Check collet according to the manufacturer's instructions. Here, check in
particular the level of pollution (clean if necessary) and that sufficient
lubrication is present (relubricate If necessary). Relubricate only after
cleaning.
4.
Degreasing of the collets may cause technical problems.
Possible causes:
- A faulty seal in the clamping taper.
- A cleaning spray directed immediately at the collet.
- Use of a degreasing medium.
Determine the causes of rapid defatting of the collet. If in doubt, always contact
the respective manufacturer.