- Check hydraulic system (visual inspection)
Orientation
To ensure trouble-free operation, periodic checks of the oil level are necessary. The
fill level must be between the upper and lower marks on the oil sight glass.
Only use hydraulic fluid grade 15/13/10 in accordance with ISO 4406.
Viscosity other than 32 according to DIN ISO 3448 is not admissible.
For all work in connection with operating materials, the information in
the data sheets of the respective manufacturers and the information
in the document Notes on Operating Materials must be observed.
Example: Hydraulic unit G200.2
a
Filler neck
b
Fill level indicator
c
Accumulator drain valve
d
Monitoring (level and temperature)
e
Oil drain plug
f
Monitoring (system pressure)
X
Hydraulic fluid filter hydraulic fluid HLPD32 (VG32)
Y
Filter bowl
Screws on the hydraulic system, the connected components, and the
supply lines must be tightened to the manufacturer's specified
torques.
Maintenance Summary - Care activities
9
Maintenance Instructions
G200.2
DIE078EN - 05.06.2019
Содержание G200.2
Страница 6: ...Table of contents IV Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 10: ...Preface 4 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 40: ...Maintenance Summary Care activities 34 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 70: ...Maintenance Summary 2 000 Operating hours 64 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 94: ...Maintenance Summary 4 000 Operating hours 88 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 99: ...Service Interval 5 Years Service Interval 5 Years 93 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...
Страница 103: ...Service Interval 8 Years Service Interval 8 Years 97 Maintenance Instructions G200 2 DIE078EN 05 06 2019 ...