- Checking the guidance and support elements as well as the slidable lattice grate of the
telescopic cover
Orientation
Check the guidance and support elements of the telescopic cover for wear
symptoms (e.g., traces of abrasion) or damage. Worn or defective guidance or
support elements must be replaced immediately.
Procedure
1. Clean and oil telescopic cover.
2.
Example: Telescopic cover with slidable lattice grate (in the drive area)
Check guidance and support elements of the telescopic cover.
3. Check the slidable lattice grate for wear.
Alternatively, the following procedure can be used!
To do so, position the respective tool carrier in the center between the two end
positions and determine the sag of the slidable lattice grate. If the sag is more
than 5 mm, the slidable lattice grate must be repaired immediately.
Maintenance Summary - 2.000 Operating hours