19
GB
A
V
Checking the connection for leaks
When the installation process is complete, check the
hose fittings for leaks using a soapy solution. Never
use a flame.
Adapting to different types of gas
It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).
Adapting the hob
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a 7 mm socket spanner
(
see fi gure
), and replace them with nozzles suited to
the new type of gas(
see Burner and nozzle specifi cations
table
).
3. Replace all the components
by following the above
instructions in reverse.
Adjusting the hob burners’
minimum setting:
1. Turn the tap to the minimum
position.
2. Remove the knob and adjust the regulatory screw,
which is positioned inside or next to the tap pin, until
the flame is small but steady.
!
If the appliance is connected to a liquid gas supply,
the regulatory screw must be fastened as tightly as
possible.
3. While the burner is alight, quickly change the position of
the knob from minimum to maximum and vice versa several
times, checking that the flame is not extinguished.
!
The hob burners do not require primary air
adjustment.
Adapting the oven
Replacing the oven burner nozzle:
1. Remove the oven compartment.
2. Slide out the protection panel A
(
see diagram
).
3. Remove the oven burner
after unscrewing the screws V
(
see fi gure
).
The whole operation will be
made easier if the oven door is
removed.
4. Unscrew the nozzle using a
special nozzle socket spanner
(
see fi gure
) or with a 7 mm
socket spanner, and replace it
with a new nozzle that is suited
to the new type of gas (
see
Burner and nozzle specifi cations table
).
Adjusting the gas oven burner’s minimum setting:
1. Light the burner (
see Start-up and Use
).
2. Turn the knob to the minimum position (MIN)
after it has been in the maximum position (MAX) for
approximately 10 minutes.
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the
outside of the thermostat pin (
see fi gure
) until the flame
is small but steady.
!
If the appliance is connected to liquid gas, the
adjustment screw must be fastened as tightly as
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Adapting the grill
Replacing the grill burner nozzle:
1. Remove the oven burner after loosening screw V
(
see fi gure
).
2. Unscrew the grill burner
nozzle using a special nozzle
socket spanner (
see fi gure
) or
preferably with a 7 mm socket
spanner, and replace it with a
new nozzle that is suited to the
new type of gas (
see Burner and
nozzle specifi cations table
).
!
Be careful of the spark plug
wires and the thermocouple
tubes.
!
The oven and grill burners do
not require primary air adjustment.
!
After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
V
I
!
Perform the connection in such a way that the hose
length does not exceed a maximum of 2 metres,
making sure that the hose is not compressed and does
not come into contact with moving parts.
Содержание C 34S G3 R /HA S
Страница 63: ...KZ 63 ...
Страница 64: ...KZ 64 03 2013 195103561 02 XEROX FABRIANO ...