Indal LIBRA Series Скачать руководство пользователя страница 1

MONTAGE VOORSCHRIFT
INSTALLATION INSTRUCTIONS
MONTAGEANWEISUNG

INSTRUCCIONES DE MONTAJE

INSTRUCTION D’ INSTALLATION

INSTRU

Ç

ES DE MONTAGEM

LIBRA

2565/2566/2567/2570/2571/2572

P1

2571

2572

2565

2566

2567

2570

IK

08

IP

66

4mm

5mm

Nr..

W

Max

Min

Kg

Max

39

5.5-5.8

0.083

-20 C

2565/66

FSD 36

40 C

45

6.6-7.0

0.095

-20 C

2570/71

FSD 40

40 C

62

6.6-7.0

0.095

-20 C

2570/71

FSD 55

40 C

86

6.6-7.0

0.095

-20 C

2570/71

FSD 80

40 C

19

5.5-5.8

0.083

-20 C

2565/66

FSD 18

40 C

05

27

5.5-5.8

0.083

-20 C

2565/66

FSD 24

40 C

m

2

0.10

0.13

0.13

0.13

0.10
0.10

Cx s

IP

65

T20

2

Louvers table

2

1

3

4

5

6

7

8

9

10

11

-

5

PLL 18

-

4

PLL 36

-

6

PLL 40/55/80

5 10

G2

-

-

-

0

-

4&6

PLL 18

-

3&6

PLL 36

-

4&8

PLL 40/55/80

5 10

G1

-

-

-

0

5 10

G3

0

-

-

PLL 40/55/80

-

-

-

PLL 18

-

-

-

PLL 24/36

-

-

5

PLL 24

-

-

4&6

PLL 24

-

1

Data subject to change. Rev. Date: 18/02/2010 

 

183

 

773

 

213

922

 

213

 183

922

 213

 

183

 

183

 

773

 

213

922

 

213

 

183

 

183

 

773

 

213

Operation instructions for Indal light fitting type Libra 65 and 70 
Please read the instructions carefully before starting any works! 
 

Content: 

 

1.

 

Safety instructions 

2.

 

Conformity with standards 

3.

 

Technical data 

4.

 

Installation & installation instructions 

5.

 

Taking into operation 

6.

 

Maintenance 

 

1.

 

Safety instructions 

 
For skilled electricians and trained personnel in accordance with national legislation, 
including the relevant standards. 
 
Observe the national safety rules and regulations for prevention of accidents and the following 
safety instructions: 
 

·

 

The technical data indicated on the lighting fitting and the gear are to be observed. 

·

 

Changes to the design and modification to the light fitting are not permitted. 

·

 

The light fitting shall be operated as intended and in undamaged and perfect condition. 

·

 

Repairs may only be carried out by a qualified “electrician”. 

·

 

Do not keep these operation instructions inside the fitting during operation. 

 

2.

 

Conformity with standards 

 

·

 

This lighting fitting meets requirements of EN 60 598. 

·

 

It has been designed, manufactured and tested as a state of art product and according 
to EN ISO 9001-2000 quality management system. 

·

 

It has been ENEC tested, certificate KEMA 2096704.01. 

·

 

It meets CE requirements. 

 

3.

 

Technical data 

 
Technical details are stated on the product label. This label states lamp type, lamp wattage, 
supply voltage and frequency, power factor/cos phi, nominal current, electrical insulation 
class (if class 2, double insulated), maximum ambient temperature (if nothing stated the 
maximum ambient temperature is 25°C), IP value, CE mark and ENEC mark (if applicable 
for this version). 
 

·

 

Ingress Protection: IP 65 complete (standard). Option of IP 66 available.  

·

 

Supply terminal: Terminal block (standard). Option of plug-socket or circuit breaker 
available. 

·

 

Storage temperature in original packaging: -40°C to +60°C. 

·

 

Cable gland: 1 x M20, for round cables of 7-14mm in diameter. 

·

 

Mounting fixation Libra 2565/2567 and 2570/2572: 2 x M10, 20Nm. 

·

 

Mounting fixation Libra 2566 and 2571: 1 x M10, 20 Nm. 

1.

 

Installation 

 

·

 

Observe the respective national regulations as well as the general rules of engineering 
which apply to the installation and operation of electrical apparatus. Transport and 
storage of the luminaire is permitted in original packaging and specified position only. 

·

 

Installation instructions are included in the packaging of each luminaire. 

·

 

Only use such lamps that have been certified for these light fittings. See type label on 
the packaging or in the luminaire for the intended type. 

 

2.

 

Taking into operation 

 
Prior to operation, check the light fitting for its proper functioning and installation in 
compliance with these operation instructions, the installation instructions and other applicable 
regulations. 
 

3.

 

Maintenance (every 4 years or at lamp change; whatever is the shortest period) 

 
The manufacturer guarantee is subject to the effective and scheduled fulfilment of the 
mentioned regular maintenance tasks, by specifically skilled and authorised workers, as well 
as to the information (regular shipment of maintenance or repair reports), and also to the lack 
of changes in the luminaires working condition (vibration levels, traffic, environment, etc.). 
 
Observe the national regulations applicable to the maintenance, servicing and testing of 
electrical apparatus as well as the general rules of engineering. 
 
Servicing: 
 
When servicing, in particular those components that affect the type of protection, will have to 
be checked and replaced if applicable, e.g.; 
 

·

 

Housing and bowl for any cracks or damages e.g. in paint finish. 

·

 

Gaskets for their perfect condition. Grease the gasket with acid-free grease. 

·

 

Terminals for their firm fit. 

·

 

In case of IP 66 rating, cleaning of the interior of the luminaire should not be 
necessary. 

·

 

Because of risk of electrostatic charge, the light fitting shall only be cleaned with a 
damp cloth or sponge. Only use customary household wash-up liquid diluted in water 
as specified. The water temperature may be hand warm. After cleaning, rinse with 
clear water. 

·

 

Lamp replacement: keep replacement intervals as specified by the lamp manufacturer. 

 
Repair: 
 
Prior to replacing or removing any components or lamps, observe the following: 

·

 

Even though this lighting fitting may (optionally) be equipped with a circuit breaker, 
we advice to disconnect the lantern from the power supply before opening or carrying 
out repairs! 

·

 

Only use genuine Indal spare parts. 

Отзывы: