Страница 1: ...Instruction manual fortheTKSeriesVerticalLinesetsupportsystem ...
Страница 2: ...he TK fitting is not compromised Determine the position of a fixed midpoint along the length of the vertical lineset pipe length This acts as a fulcrum to direct the thermal expansion and contraction upwards and downwards from the midpoint supporting the weight of the lineset and reducing the load on the fitting at the lowest floor by 50 Drawing 1 Use only on vertical risers of 165 feet or less Fo...
Страница 3: ...e masonary or block wall use the TK K bracket and ensure it is firmly anchored Drawing 2 Selection positioning and set up of pipe support Select only correct TK model to suit lineset to be supported Drawing 3 Front of Pipe Support Ferrule Size Marking Example of TK 7K ZA When fitting pipe support ferrule around pipe the interlocking edges on the right hand vertical seam must engage completely with ...
Страница 4: ...on Check for mounting position of Pipe Support Ferrule Place ferrule around pipe so size marking faces the installer drawing 3 and clamp it onto the pipe surface ensuring that the centerline of the ferrule is aligned with the centerline of the mounting bracket drawing 4 Check that mounting position of ferrule is correct by temporarily fitting the fixing clamp around the ferrule drawing 5 to confir...
Страница 5: ... surface of ferrule and pipe surface is completely filled with brazing material to eliminate possibility of water droplets forming in any crevices and possibly deforming pipe due to expansion caused by freezing Entire circumference of upper edge Braze entire circumference of upper edge Drawing 6 Drawing 6 Copper pipe Pipe Support Ferrule Brazing material Ensure that pipe and ferrule edge are corre...
Страница 6: ...en the 2 ferrule halves and ensure that the gap is completely filled with brazing material Brazing material Brazing material Section Heat up the area between the open ends of the raised flange Apply brazing material and ensure this area is completely filled as well Ensure that the entire surface of the gap is completely filled Flange part Root Pipe Support Ferrule Copper pipe Pipe Support Ferrule ...
Страница 7: ...with brazing material Brazing material Brazing material Section Heat up the area between the open ends of the raised flange Apply brazing material and ensure this area is completely filled as well Ensure that the entire surface of the gap is completely filled Flange part Root Braze straight vertical seam and flange on opposite side Drawing 11 14 Pipe Support Ferrule Copper pipe Pipe Support Ferrul...
Страница 8: ...ing work Check for integrity of brazing material on all brazed surfaces of ferrule Cool down brazed ferrule assembly with damp cloth Filled brazing material may flow downwards when heat is applied to an adjacent section In this case rebraze affected part After cooling ferrule attach fixing clamp around ferrule and attach to mounting bracket drawing 16 Pipe Support Ferrule Drawing 16 IF fixing clam...
Страница 9: ...n mounting bracket wrap it with Inaba Adhesive tape HF 50 HV 50 Coat open ends of insulation sleeve with silicone sealant to seal it onto the mounting bracket Seal horizontal insulation seams by wrapping them with Inaba Insulation joint adhesive tape JTA 100 I centering it on joint and overlapping ends at least drawing 18 Drawing 19 Drawing 18 Insulation Joint Adhesive Tape Slit part of Insulation...