A-8
MForce MicroDrive Motion Control Hardware Manual Revision R112706
Enhanced I/O Set Interfacing and Application
NPN Sinking Input
Application Example
Sensor using the HOME function.
‘[VARIABLES]
S2=1,1,0 ‘Configure IO2 as a Home Input, active HIGH, sinking.
Enter to IMS Terminal in Immediate mode or in a Program
HM 1
‘Slew at VM - until IO2 = 1, Creep off + at VI
PNP Sourcing Input
Application Example
Sensor using the Jog+ function.
JE=1
‘Enable Jog function
S11=7,1,1 ‘Configure IO11 as a Jog+ Input, active HIGH, sourcing
Internal
pull-up
voltage
detect
logic
24.9k ohms
100k ohms
3.3 V
The internal pull-up voltage
cannot provide output
current / voltage
IOPWR
IOGND
Iil
65 - 160 uA
MForce Plus2
IOx
Vih = 2.31 V
Vil = 0.99 V
Threshold (nom) = 1.5 V
Iil = 100 µA
NPN Input, Sinking
Sinking Input Equivalent Circuit
NPN
12 to
24 V
+
Figure B.5: NPN Sinking Input on an MForce Plus2 Motion Control
PNP Input, Sourcing
Internal
pull-up
voltage
detect
logic
40 - 135 uA
24.9k ohms
100k ohms
3.3 V
The internal pull-up voltage
cannot provide output
current / voltage
IOPWR
IOx
IOGND
Iih
MForce Plus
2
Vih = 2.31 V
Vil = 0.99 V
Threshold (nom) = 1.5 V
Iih = -1.24 mA
PNP
12 to
24 V
Figure B.6: PNP Sourcing Input on an MForce Plus2 Motion Control
Содержание Mforce micro drive
Страница 8: ...vi Page Intentionally Left Blank ...
Страница 14: ...This Page Intentionally Left Blank ...
Страница 16: ...1 8 Motion Control MForce MicroDrive Hardware Manual Revision R112706 Page Intentionally Left Blank ...
Страница 32: ...2 2 Motion Control MForce MicroDrive Hardware Manual Revision R112706 This Page Intentionally Left Blank ...
Страница 68: ...A 2 MForce MicroDrive Motion Control Hardware Manual Revision R112706 ...