2-5
Part 2: Connections and Interface
Figure 2.1.3: MForce MicroDrive Power Connections
Unregulated
Linear or
Switching
Power Supply
Power
Ground
+VDC
Shield to
Earth Ground
+
–
Shielded Twisted Pair Cable 18 AWG
!
WARNING! Do not connect
or disconnect cabling while
power is applied!
Black
Pin 6
Pin 7
Pin 16
Pin 15
Red
1 2 3 4 5 6 7
7-Pin Pluggable Terminal
16-Pin Wire Crimp
12” Flying Leads
A
B
B
B
B
A
A
P1
P1
A
B
B
+V Voltage: +12 to +48* VDC
+V Current: 2A Max Per MForceMicroDrive
Recommended IMS Power Supplies:
ISP200-4
IP402
IP404
*Includes Back EMF!
Power Supply Connection