2-11
Part 2: Interfacing and Configuring
MDrive34Plus Recommended Power Supply Cable AWG
1 Amperes (Peak)
3 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
20
18
18
16
Minimum AWG
18
16
14
12
12
2 Amperes (Peak)
4 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
18
16
14
14
Minimum AWG
18
16
14
12
12
*Use the alternative methods illustrated in examples B and C when cable length is ≥ 50 feet. Also, use the same
current rating when the alternate AC power is used.
Table 2.2.1: Recommended Wire Gauges